User Guide

8
WOLF DUAL FUEL RANGES
19" (483)
LOCATION OF
ELECTRICAL
36"
(914)
36
7
/8"
(937) TO
COOKING
SURFACE
VENTILATION HOOD
COMBUSTIBLE CONSTRUCTION
18"min (457)
TO COUNTERTOP
13"max
(330)
LOCATION OF GAS AND
ELECTRICAL EXTENDS 3" (76)
ON FLOOR FROM BACK WALL
ISLAND INSTALLATIONS: 12" (305) MIN
CLEARANCE FROM BACK OF RANGE
TO COMBUSTIBLE CONSTRUCTION
36" (914)
FINISHED ROUGH OPENING WIDTH
3
1
/4"
(83)
8
1
/2"
(216)
15" (381)
LOCATION
OF GAS
SUPPLY
30"min (762) TO
36"max (914)
TO BOTTOM OF
VENTILATION HOOD
36"min (914)
COUNTERTOP
TO COMBUSTIBLE
CONSTRUCTION
44"min (1118)
FOR CHARBROILER
6"min
(152)
TO WALL
35
7
/8" (911)
OVERALL WIDTH
41
7
/8"
(1064)
WITH 5"
RISER
46
7
/8"
(1191)
WITH 10"
RISER
56
7
/8"
(1445)
W
ITH 20"
RISER
47" (1194)
24
1
/4"
(616)
27
1
/2" (699)
9
1
/4"
(235)
29
1
/2" (749)
OVERALL DEPTH
LEGS AND CASTERS ALLOW
2
1
/8" (54) HEIGHT ADJUSTMENT
35
7
/8"
(911)
36
7
/8"
(937)
OVERALL
HEIGHT TO
COOKING
SURFACE
INSTALLATION SPECIFICATIONS
OVERALL DIMENSIONS
O
verall Width 35
7
/8"
(911)
Overall Height
(to cooking surface) 36
7
/8" (937)
O
verall Depth 29
1
/2"
(749)
Opening Width 36" (914)
D
imensions may vary to
±
1
/8"
(3).
36" (914) DUAL FUEL RANGES
IMPORTANT NOTE:
In non-island appli-
cations, a minimum
5" (127) riser is
required for Model
DF366 and minimum
10" (254) riser
required for Models
DF364C and DF364G
installed against a
combustible surface.
The island trim and
5" (127) riser may
only be used against
a non-combustible
surface for Models
DF364C and DF364G.