WOLF GAS RANGETOPS
MINIMUM CLEARANCES
IMPORTANT NOTE:
Caution must be used in
planning the proper installation of the Wolf gas
r
angetop to avoid fires or damage to adjacent
cabinetry or kitchen equipment. Be sure to
follow the minimum clearances established in
t
he finished rough opening dimensions.
R
efer to the Installation Specifications
illustrations for your model on pages 8–9 for
the exact rough opening dimensions.
WALL INSTALLATIONS
Minimum clearances to combustible
surfaces:
Minimum 18" (457) clearance from bottom
of upper cabinet to countertop, within 6"
(152) minimum side clearance.
Minimum spacing between overhead side
cabinets must be greater than or equal to
the nominal width of the rangetop. The
maximum depth of overhead and side
cabinets is 13" (330), within 6" (152) side
clearance.
0" (0) clearance for adjacent combustible
materials below the countertop, both sides
and rear.
Bottom of ventilation hood must be 30"
(762) minimum to 36" (914) maximum from
counter
top.
INSTALLATION SPECIFICATIONS
Wolf gas rangetops come in 36" (914) and 48"
(1219) widths. Illustrations on pages 8–9
p
rovide the overall dimensions and installation
specifications for each width of gas rangetop.
Refer to the Installation Specifications illustra-
tion for your model on pages 8–9 for the exact
r
ough opening dimensions and location of the
gas and electrical supply.
IMPORTANT NOTE:
Cabinet opening dimen-
sions shown in the Installation Specifications
illustrations must be used. These dimensions
provide for required clearances.