Planning Information
GAS SUPPLY
Installation must comply with all applicable gas codes.
A gas supply line of
3
/4" (19) rigid pipe must be provided to
the cooktop. If local codes permit, a certied, 3'
(.9 m) long,
1
/2" (13) or
3
/4" (19) ID exible metal appliance connector is
recommended to connect the units
1
/2" NPT male inlet to
the gas supply line.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
in altitude without adjustment and LP gas cooktops
will function up to 8,600'
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)