Tus neeg siv phau ntawv
BUILT-IN FAULT CODE TROUBLESHOOTING GUIDE
FAULT CODE TROUBLESHOOTING GUIDE
Code Service
Icon
State
Description and Action
10 1 00 On
Refrigerator cabinet thermistor open.
Verify temperature reading and ohm thermistor.
Replace thermistor if bad.
10 1 01 On
Refrigerator cabinet thermistor shorted.
Verify temperature reading and ohm thermistor.
Replace thermistor if bad.
10 1 02 On
Refrigerator cabinet thermistor unstable.
Check for bad connections and/or damaged
wires. Repair connection or wire.
10 2 00 On
Freezer cabinet thermistor open.
Verify temperature reading and ohm thermistor.
Replace thermistor if bad.
10 2 01 On
Freezer cabinet thermistor shorted.
Verify temperature reading and ohm thermistor.
Replace thermistor if bad.
10 2 02 On
Freezer cabinet thermistor unstable.
Check for bad connections and/or damaged
wires. Repair connection or wire.
10 3 00 On
Condenser thermistor open.
Verify temperature reading and ohm thermistor.
Replace thermistor if bad.
10 3 01 On
Condenser thermistor shorted.
Verify temperature reading and ohm thermistor.
Replace thermistor if bad.
10 3 02 On
Condenser thermistor unstable.
Check for bad connections and/or damaged
wires. Repair connection or wire.
10 3 10 This code is inactive. Please ignore.
10 3 11 This code is inactive. Please ignore.
10 3 12 This code is inactive. Please ignore.
10 7 00
Ambient thermistor open.
Verify temperature reading. Replace control
board if temperature is not correct.
10 7 01
Ambient thermistor shorted.
Verify temperature reading. Replace control
board if temperature is not correct.
FAULT CODE TROUBLESHOOTING GUIDE
Code Service
Icon
State
Description and Action
10 7 02
Ambient thermistor unstable.
Verify temperature reading. Replace control
board if temperature is not correct.
10 F 00 On
Freezer evaporator thermistor open.
Verify temperature reading and ohm thermistor.
Replace thermistor if bad.
10 F 01 On
Freezer evaporator thermistor shorted.
Verify temperature reading and ohm thermistor.
Replace thermistor if bad.
10 F 02 On
Freezer evaporator thermistor unstable.
Check for bad connections and/or damaged
wires. Repair connection or wire.
10 r 00 On
Refrigerator evaporator thermistor open.
Verify temperature reading and ohm thermistor.
Replace thermistor if bad.
10 r 01 On
Refrigerator evaporator thermistor shorted.
Verify temperature reading and ohm thermistor.
Replace thermistor if bad.
10 r 02 On
Refrigerator evaporator thermistor unstable.
Check for bad connections and/or damaged
wires. Repair connection or wire.
10 r 09
Refrigerator evaporator thermistor read higher
than cabinet thermistor by at least 10 degrees.
Error may indicate problem with thermistor or a
unique evaporator issue.
15 1 00
Flash
with
Chime
Refrigerator compressor relay stuck open. No
power to compressor.
Verify refrigerator compressor relay stuck open.
Replace control board.
15 1 01
Flash
with
Chime
Refrigerator compressor relay stuck closed.
Power to compressor at all times.
Verify refrigerator compressor relay stuck
closed. Replace control board.
15 2 00
Flash
with
Chime
Freezer compressor relay stuck open. No power
to compressor.
Verify freezer compressor relay stuck open.
Replace control board.
15 2 01
Flash
with
Chime
Freezer compressor relay stuck closed. Power
to compressor at all times.
ICBBI-42UFDID
Troubleshooting
service.subzero.com
7041397 REVA 12/2017
155