Electrical Requirements
Locate the electrical supply within the shaded area shown
in the illustrations below. A separate circuit servicing only
this appliance is required.
IMPORTANT NOTE: For 24" models, the electrical outlet
must be positioned with the grounding prong to the right
of the thinner blades.
IMPORTANT NOTE: For outdoor models UC-24RO and
UC-15I(P)O, a ground fault circuit interrupter (GFCI) is
required to reduce the risk of electrical shock. A GFCI
is not recommended for use with other Undercounter
models and may cause interruption of operation.
Installation must comply with all applicable electrical codes.
3" (76)
15
1
/2"
(394)
2"
(51)
LEFT SIDE
OF OPENING
FLOOR
E
E
LOCATE
ELECTRICAL
SUPPLY IN
ADJACENT
CABINET
24" Models
Ice maker
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Undercounter Refrigeration