Installation Guide

6 | Sub-Zero Customer Care 800.222.7820
Preparation
Uncrate the unit and inspect for damage. Remove the wood
base and discard the shipping bolts and brackets. Remove
and recycle packing materials. Do not discard the kickplate,
anti-tip bracket, and hardware.
Remove the kickplate by extracting the two mounting
screws. Refer to the illustration below.
Anti-Tip Bracket
WARNING
To prevent the unit from tipping forward, the anti-tip
bracket must be installed.
The back of the anti-tip bracket must be installed 24" (610)
from the front of the unit (without panels). Use all anti-tip
bracket hardware as instructed for wood or concrete oors.
IMPORTANT NOTE: For wood or concrete oor applications,
if the #12 screws do not hit a wall stud or wall plate, use the
#8 screws and #12 washers with the wall anchors.
IMPORTANT NOTE: In some installations, the subooring or
nished oor may necessitate angling the screws used to
fasten the anti-tip bracket to the back wall.
SITE PREPARATION
SCREW
Kickplate removal
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
For model IW-30CI, the water supply line should be located
within the shaded area shown in the illustration below.
The water supply line should be connected to the house
supply with an easily accessible shut-off valve. Do not use
self-piercing valves. The water supply line must be ush to
the oor and not interfere with the installation of the anti-tip
bracket.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar) supplied
to the unit at all times. In this application, the water ltra-
tion system must be bypassed. Refer to Water Filter Bypass
on page 15. A copper line is not recommended for this
application.
PLUMBING REQUIREMENTS
Water Supply Line
1
/4" OD copper, braided
stainless steel, or PEX tubing
Water Pressure 35–120 psi
(2.4–8.3 bar)
Excess Water Line for Connection 36" (914)
WATER SUPPLY LOCATION
A
IW-30CI 6" (152)
3" (76)
6" (152)
RIGHT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
A
Water supply location (IW-30CI)