design guide

subzero.com/specs
|
65
ELECTRICAL SUPPLY LOCATION
INTEGRATED MODEL A
18" Model 6" (152)
24" Model 9
1
/2" (241)
30" Model 12
1
/2" (318)
Electrical
The electrical supply must be located within the shaded
area shown in the illustration for your specic model. For
integrated (IW) models, also refer to the chart. For model
315W, the electrical supply can be located anywhere on the
back wall of the opening. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
If the unit will be connected to a home security system,
allow 36"
(914) of excess wiring for proper connection.
IMPORTANT NOTE: For integrated (IW) models, the electrical
outlet must be positioned with the grounding prong to the
right of the thinner blades.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp
Receptacle 3-prong grounding-type
WINE STORAGE
3" (76)
15
1
/2"
(394)
2"
(51)
LEFT SIDE
OF OPENING
FLOOR
75
1
/2" (1918)
FROM FLOOR
7"
(178)
E
6"
(152)
RIGHT SIDE
OF OPENING
Model 424G.
Model WS-30.
A
1
/4" (6)
1
/4" (6)
4
1
/4"
(108)
4
1
/2"
(114)
FLOOR
LEFT SIDE
OF OPENING
Integrated models.
BUILT-IN PRO 48 INTEGRATED WINE UNDERCOUNTER