User Guide

71
Dimensions in parentheses are in
millimeters unless otherwise specified.
PLANNING INFORMATION
Refer to the Installation Specifications for infor-
mation regarding area requirements, minimum
door clearance, placement of electrical and
plumbing (Model UC-24C).
PLUMBING REQUIREMENTS
For Model UC-24C, rough in the water supply
line. Connect a
1
/4" OD copper line to the house
supply with an easily accessible shut-off valve
between the supply and the unit. A minimum of
26" (660) of copper tubing is required for the
water line.
Do not use self-piercing valves. A saddle valve
kit (4200880) is available from your Sub-Zero
dealer. An in-line filter is required when water
conditions have a high sediment content.
The ice maker operates on constant water
pressure between 20 psi (1.4 bar) and 100 psi
(6.9 bar).
IMPORTANT NOTE: In some cases, a reverse
osmosis water filter system may not be able to
maintain the minimum pressure consistently.
ELECTRICAL REQUIREMENTS
A 115 V AC, 60 Hz, 15 amp circuit breaker and
electrical supply are required. A separate circuit,
servicing only this appliance is required.
All Undercounter models are equipped with a
power supply cord with a 3-prong grounding
plug, which must be plugged into a mating
3-prong grounding-type wall receptacle. Follow
the National Electrical Code and local codes and
ordinances when installing the receptacle. Refer
to the Installation Specifications illustrations.
IMPORTANT NOTE: The Model UC-24RO is
designed and safe for use in outdoor applica-
tions. When installed outdoors, a ground fault
circuit interrupter (GFCI) is required to reduce
the risk of electrical shock. A GFCI is not
recommended for use with other Undercounter
models and may cause interruption of operation.
34
1
/2"
(876)
ROUGH
OPENING
HEIGHT
34
1
/4"
(870)
MINIMUM
HEIGHT
REQUIRED
24" (610)
ROUGH OPENING
WIDTH
15
1
/2"
(394)
24"
(610)
ROUGH
OPENING
DEPTH
LOCATE ELECTRICAL
AND WATER LINE
(MODEL UC24C ONLY)
WITHIN SHADED AREA
LOCATE WATER LINE
(MODEL UC24C ONLY)
WITHIN SHADED AREA
3"
(
76
)
2" (51)
15
1
/2"
(394)
1
/2"
(
13
)
2" (51)
TOP VIEW
FRONT VIEW
ANTI-TIP BRACKET
INSTALLATION SPECIFICATIONS
Undercounter Models
Overall Dimensions
Overall Width 23
7
/8" (606)
Overall Height 34" (864)
Overall Depth 24" (610)
Finished Opening Dimensions
Opening Width 24" (610)
Opening Height 34
1
/2" (876)
Opening Depth 24" (610)
Door Swing Clearance 25
3
/8" (645)
Models without an ice maker will not require
the water line connection.
Door swing clearance based on stainless
steel door panel and handle dimensions.
MODEL OPTIONS
Model UC-24R
All Refrigerator
Model UC-24B
All Refrigerator
Beverage Center
Model UC-24C
Refrigerator | Freezer
with Ice Maker
Model UC-24RO
All Refrigerator
Outdoor Model
NOTE: Door swing clearances are based
90˚
26" (660)
DOOR CLEARANCE
25
3
/8"
(644)