Design Guide

66 | Sub-Zero Customer Care 800.222.7820
Wine Storage
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration for your specific model. For Designer
Series models, also refer to the chart. A separate circuit
servicing only this appliance is required. A ground fault cir-
cuit interrupter (GFCI) is not recommended and may cause
interruption of operation.
If the unit will be connected to a home security system,
allow 36"
(914) of excess wiring for proper connection.
IMPORTANT NOTE: For Undercounter and Designer Series
models, the electrical outlet must be positioned with the
grounding prong to the right of the thinner blades.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
ELECTRICAL LOCATION—DESIGNER SERIES A
18" Model 6" (152)
24" Model 9⁄" (241)
30" Model 12⁄" (318)
5"
(127)
2"
(51)
4"
(102)
FLOOR
OPENING
75
1
/2" (1918)
FROM FLOOR
7"
(178)
E
6"
(152)
RIGHT SIDE
OF OPENING
Model DEU2450W Model BW-30
A
1
/4" (6)
1
/4" (6)
4
1
/4"
(108)
4
1
/
2
"
(114)
FLOOR
LEFT SIDE
OF OPENING
Designer Series models