Installation Guide

subzero.com
|
5
SITE PREPARATION
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit,
servicing only this appliance is required.
IMPORTANT NOTE: The electrical outlet must be placed so
the grounding prong is to the right of the thinner blades.
The outlet must be ush with the back wall.
Model UC-24RO is designed and safe for use in outdoor
applications. When installed outdoors, a ground fault
circuit interrupter (GFCI) is required to reduce the risk of
electrical shock. A GFCI is not recommended for use with
other undercounter models and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp
Receptacle 3-prong grounding-type
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
Plumbing
Installation must comply with all applicable plumbing codes.
For model UC-24CI, the water supply should be located
within the shaded area shown in the illustration below.
The water supply line should be connected to the house
supply with an easily accessible shut-off valve. Do not use
self-piercing valves.
A reverse osmosis system can be used provided there is
constant water pressure of 20–100 psi
(1.4–6.9 bar) supplied
to the unit at all times. A copper line is not recommended
for this application.
PLUMBING REQUIREMENTS
Water Supply
1
/4" OD copper, braided
stainless steel or PEX tubing
Pressure 20–100 psi
(1.4–6.9 bar)
Excess Line for Connection 36" (914)
3" (76)
15
1
/2"
(394)
2"
(51)
LEFT SIDE
OF OPENING
FLOOR
Electrical supply location.
3" (76)
15
1
/2"
(394)
2"
(51)
LEFT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
Water supply location.