Design Guide

subzero.com | 83
DOOR CLOSED
UNDERCOUNTER
UNIT
ADJACENT
CABINETRY
3
/4" (19) DOOR PANEL
1
/2"
(13)
1
/8" (3)
1
/4"
(6)
HINGE AT 145°
OPENING
(DOOR OPENS PAST 145°)
1" (25)0"
SCALE
145° door opening (top view)
Door Clearance—UW-24
FULL-SCALE TEMPLATE
To allow for a 145° door opening, the unit should
extend a minimum of ⁄"
(6) beyond the front surface of
adjacent cabinetry. The unit can be installed flush, how-
ever, there is potential for interference with the panel if
the door is opened past 90°.
Wine Storage