Design Guide

subzero.com | 33
Side Panel
The custom side panels must be a minimum of 24" (610)
deep and ⁄"
(13) thick. Routing will be necessary for the
side panel to fit flush against the side of the unit. Refer to
the illustrations below.
When installing a Classic series unit with a custom side
panel, an accessory kit is required. Stainless steel and white
enamel side panels are available for an 84"
(2134) finished
height through an authorized Sub-Zero dealer. For local
dealer information, visit the find a showroom section of
our website, subzero.com.
84"
(2134)
24" (610)
ROUT TO
3
/16" (5)
(OVER-AND-UNDER
MODELS)
OPTIONAL
TOE KICK
CUT-OUT
4" (102)
20
1
/2"
(521)
5
3
/4"
(146)
1
7
/8"(48)
1"
(25)
4
1
/4" (108)
ROUT TO
1
/8" (3)
FRONT
OF SIDE
PA NEL
2
5
/8"
(67)
MAIN
FRAME
SIDE PANEL
ROUTING
1" (25)
1
7
/8" (48)
1
/8" (3)
1
/
2
"
(13)
Side panel dimensions
Routing detail
Standard Handles
Optional stainless steel tubular and pro handles are avail-
able through an authorized Sub-Zero dealer. For local
dealer information, visit the find a showroom section of
our website, subzero.com.
Refer to the chart below for standard handle lengths for
Classic series models.
HANDLE LENGTH TUBULAR PRO
Full Door 63⁄" (1622) 45⁄" (1147)
Over-and-Under Door 44⁄" (1124) 37⁄" (952)
30" Drawer 24⁄" (633) 17⁄" (447)
36" Drawer 30⁄" (770) 23⁄" (600)
42" Drawer 36⁄" (922) 29⁄" (753)
Classic Series Refrigeration