WOLF PRO VENTILATION
DUCTING CONSIDERATIONS
Refer to the illustration below for ducting
considerations for Pro hood liners.
Pro wall and island hoods and hood liners will
operate most efficiently when ductwork does
not exceed 50' (15 m) in length.
Local building codes may require the use of
make-up air. Consult your local HVAC profes-
sional for specific requirements in your area.
Refer to the Pro ventilation recommendations
on pages 95–98.
12" (305)
HEIGHT OF LINER
HOOD LINER
DUCTWORK INSTALLATION
THROUGH ROOF
8" ROUND DUCT (L282212I)
10" ROUND DUCT (ALL OTHER LINERS)
SOFFIT OR CABINET
OR DUCT COVER
VERTICAL DISCHARGE ONLY FOR VENTILATION HOOD LINERS.
VERTICAL DISCHARGE
22
1
/2" (572)
DEPTH OF LINER
DECORATIVE HOOD
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
DECORATIVE HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
TRANSITION
17
3
/4"W x 4
1
/4"D TO 8" ROUND
9
3
/8"H (L282212I)
22
1
/4"W x 9"D TO 10" ROUND
10"H (ALL OTHER LINERS)
DIMENSIONS INCLUDE FLANGES
ROOF CAP OR REMOTE BLOWER –
TRANSITION FROM 8" (203) TO 10" (254) DUCT
REQUIRED FOR REMOTE BLOWER
DUCTING CONSIDERATIONS
Pro Hood Liners
INSTALLATION
Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.