User Guide

96
WOLF VENTILATION RECOMMENDATIONS
CFM
Recommendations
are based on total
Btu/hr output. Wolf
recommends 1 CFM
per 100 Btu/hr
(.03 kW). Additional
CFM may be required
for charbroilers,
griddles and long
duct runs.
I363418 I423418 I543418 I663418
DF304 / R304 / SRT304 600 600
DF366 / R366 / SRT366 / RT366 900
DF364 / R364 / SRT364 / RT364 900
RT362 900
R488 / RT488 1100
DF486 / R486 / SRT486 / RT486 1100
DF484 / R484 / SRT484 / RT484 900
R482 / RT482 900
DF606 / R606 1500
DF604 / R604 1500
PRO VENTILATION CFM RECOMMENDATIONS
MODEL
NUMBERS
Model numbers for
dual fuel ranges,
gas ranges, sealed
burner rangetops and
gas rangetops
indicate width and
number of surface
burners. Features
such as a charbroiler,
griddle and/or French
Top will vary.
PRO ISLAND HOODS
L282212I L342212 L402212 L462212 L522212 L582212
DF304 / R304 / SRT304 600
DF366 / R366 / SRT366 / RT366 900 900
DF364 / R364 / SRT364 / RT364 900 900
RT362 900 900
R488 / RT488 1100 1100
DF486 / R486 / SRT486 / RT486 1100 1100
DF484 / R484 / SRT484 / RT484 900 900
R482 / RT482 900 900
DF606 / R606 1500
DF604 / R604 1500
PRO HOOD LINERS