折り PKX series 201/301/401 201H 201ST/301ST 201T/301T ISSUE EMD-PU2117 9ZZ9990035 PRINTED IN JAPAN May 2005 CE-SK 北米 折り
1 PKX201,301,401, 201H, 201ST, 301ST 5 1 6 4 2 3 1 1 5 PKX201T, 301T 2 7 1 8 5 2 7 3 2 2 2 1 6 4 2 18 9 17 5 6 3 2 16 1 3 15 5W 10 14 20W Single grade 13 19 12 20 23 22 24 1 #40 Ambient temperature 7 3 7 #30 8 11 1 4 #20 10W-30 Multi grade 21 3 10W 10W-40 -20 -10 0 10 20 30 -4 14 32 50 68 86 104 F 40 C 4 5 8 4 1 2 PKX201T, 301T 5 4 6 1 2 3 7 0.6 - 0.
FOREWORD Thank you very much for purchasing a ROBIN PUMP. ENGLISH This manual covers operation and maintenance of ROBIN PUMP. All information in this publication is based on the latest product information available at the time of approval for printing. Please read this manual carefully before operating. Please take a moment to familiarize yourself with the proper operation and maintenance procedures in order to maximize the safe and efficient use of this product.
1. SAFETY PRECAUTIONS ENGLISH Please make sure you review each precaution carefully. Pay special attention to statement preceded by the following words. WARNING “WARNING” indicates a strong possibility of severe personal injury or loss of life if instructions are not followed. CAUTION “CAUTION” indicates a possibility of personal injury or equipment damage if instructions are not followed. FRANÇAISE WARNING : EXHAUST PRECAUTIONS ■ Never inhale exhaust gasses.
Do not touch the spark plug and ignition cable when starting and operating the engine. ■ Operate the pump on a stable, level surface. If the engine is tilted, fuel spillage may result. ENGLISH ■ NOTE Operating the pump at a steep incline may cause seizure due to improper lubrication even with a maximum oil level. ■ Do not transport the pump with fuel in tank or with fuel strainer cock open. ■ Keep the unit dry (do not operate it in rainy conditions).
SYMBOLS ENGLISH Read the owner's manual. Stay clear of the hot surface. Exhaust gas is poisonous. Do not operate in an unventilated area. FRANÇAISE Stop the engine before refueling. Fire, open flame and smoking prohibited. On (Run) Plus ; Positive polarity Off (Stop) Battery Engine oil Engine start (Electric start) ESPAÑOL Add oil 4 PKX(US)_PU2117.p7 Page 4 05.8.3, 7:11 PM Adobe PageMaker 7.
2. COMPONENTS (See Fig. 1) ENGLISH NOTE Please refer to the illustrations on the back page of the front cover or back cover for Fig. 1 to i indicated in the sentence.
3. PRE-OPERATION FOR STARTING ENGLISH (See Fig. 2) 1. CONNECT SUCTION HOSE q) (See Fig. 2-q 4. CHECK FUEL t) (See Fig. 2-t Use a reinforced-wall or wire braided hose to prevent suction collapse. Since the pump self-priming time is directly proportional to hose length, a short hose is recommended. WARNING Do not refuel while smoking, near an open flame or other such potential fire hazards. Otherwise fire accident may occur. CAUTION FRANÇAISE Always use a strainer with the suction hose.
4. OPERATING YOUR PUMP (2) Turn the STOP SWITCH to the position “ I ” (ON). (See Fig.3-w) (1) Set the speed control lever at the low speed position and allow the engine to run at low speed for 1 or 2 minutes before stopping. (See Fig.5-q) (3) Set the speed control lever 1/3 of the way towards the high speed position. (See Fig.3-e) (2) Turn the STOP SWITCH counterclockwise to the position “ ⃝ ” (OFF). (See Fig.5-w) (4) Close the choke lever. (See Fig.
ENGLISH 2. PERIODIC INSPECTION Periodic maintenance is vital to the safe and efficient operation of your pump. Check the table below for periodic maintenance intervals. IT IS ALSO NECESSARY FOR THE USER OF THIS PUMP TO CONDUCT THE MAINTENANCE AND ADJUSTMENTS ON THE EMISSION-RELATED PARTS LISTED BELOW TO KEEP THE EMISSION CONTROL SYSTEM EFFECTIVE. The maintenance schedule indicated in the following table is based on the normal engine operation.
Recommended Spark Plug : NGK BR-6HS (CHAMPION RL86C) w,e e) 4. ENGINE OIL CHANGE (See Fig. 7-w Initial oil change Thereafter WARNING CAUTION ■ Remove the element and wash it in kerosene or diesel fuel. Then saturate it in a mixture of 3 parts kerosene or diesel fuel and 1 part engine oil. Squeeze the element to remove the mixture and install it in the air cleaner. (2) Urethane Foam Dual Element Type (See Fig.7-y) ■ Urethane Foam cleaning (See Fig.
6. PREPARATIONS FOR STORAGE 8. SPARK ARRESTER (OPTIONAL) q) 8-q 1. WATER (See Fig.8 1. SPARK ARRESTER ENGLISH Drain all water from the drain plug. CAUTION When retightening drain plug, be sure to clean the drain plug and the thread of casing. Otherwise, the thread may be damaged. 2. DISCONNECT THE DELIVERY HOSE Tilt the pump and drain all water from delivery hole. Severe damage to pump may result if water freezes in the pumping chamber. e) 8-e 3. DISCHARGE FUEL (See Fig.
9. EASY TROUBLESHOOTING 2. PUMPING VOLUME IS SMALL. ■ Sucking air at suction side. (Check piping at suction side.) ■ Drop off engine output (Consult your nearest dealer.) ■ Breakage of mechanical seal. (Consult your nearest dealer.) ■ High suction lift (Lower.) ■ Suction hose is too long or thin. (Use a thick hose in minimum length.) ■ Leak of water from water passage. (Stop leaking.) ■ Clogging of foreign substance in impeller. (Disassemble and clean.) ■ Wear of impeller.
10. SPECIFICATIONS MODEL PKX201 PKX301 Total Head m(ft) Maximum Delivery Volume Liter(U.S.
折り PKX series 201/301/401 201H 201ST/301ST 201T/301T ISSUE EMD-PU2117 9ZZ9990035 PRINTED IN JAPAN May 2005 CE-SK 北米 折り