PTX201D PTX301D ISSUE EMD-PU2365 PRINTED IN JAPAN May 2007 9ZZ9990051
1 4 5 3 3 6 1 3 7 2 8 1 4 19 2 5W 9 10W 20W Single grade 15 #20 #30 16 #40 14 17 13 10W-30 Multi grade 10W-40 Ambient temperature 12 3 -20 -10 0 10 20 30 -4 14 32 50 68 86 104 F 40 C 5 11 18 20 10 1 19 2 3 4 21 23 22 24 6 1 2 2 1 7 5 8 6 1 2 1 3 2
PTX301D ce_PU2365 07.5.14 4:08 PM ページ02 4 5 6 4 1 5 6 2 1 2 2 7 8 6 1 3 7 5 1 1 8 1 0.6 - 0.
ENGLISH PTX301D ce_PU2365 07.5.14 4:08 PM ページ03 NOTICE ESPAÑOL FRANÇAISE FEDERAL EMISSION COMPONENT DEFECT WARRANTY and CALIFORNIA EMISSION CONTROL WARRANTY are applicable to only those engines/ generators complied with EPA (Environmental Protection Agency) and CARB (California Air Resources Board) emission regulations in the U.S.A. NOTICE To the engines/generators exported to and used in the countries other than the U.S.A.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ04 FEDERAL EMISSIONS COMPONENT DEFECT WARRANTY EMISSIONS COMPONENT DEFECT WARRANTY COVERAGE – This emission warranty is applicable in all States, except the state Fuji Heavy Industries Ltd. and Robin America Inc.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ1 FOREWORD Thank you very much for purchasing a ROBIN PUMP. ENGLISH This manual covers operation and maintenance of ROBIN PUMP. All information in this publication is based on the latest product information available at the time of approval for printing. Please read this manual carefully before operating. Please take a moment to familiarize yourself with the proper operation and maintenance procedures in order to maximize the safe and efficient use of this product.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ2 SAFETY PRECAUTIONS Please make sure you review each precaution carefully. ENGLISH Pay special attention to statement preceded by the following words. WARNING “WARNING” indicates a strong possibility of severe personal injury or loss of life if instructions are not followed. CAUTION “CAUTION” indicates a possibility of personal injury or equipment damage if instructions are not followed.
■ Do not touch the ignition cable when starting and operating the engine. ■ Operate the pump on a stable, level surface. If the engine is tilted, fuel spillage may result. ENGLISH PTX301D ce_PU2365 07.5.14 4:08 PM ページ3 NOTE Operating the pump at a steep incline may cause seizure due to improper lubrication even with a maximum oil level. ■ Do not transport the pump with fuel in tank or with fuel strainer cock open. ■ Keep the unit dry (do not operate it in rainy conditions).
PTX301D ce_PU2365 07.5.14 4:08 PM ページ4 SYMBOLS ENGLISH Read the owner's manual. Stay clear of the hot surface. Exhaust gas is poisonous. Do not operate in an unventilated area. FRANÇAISE Stop the engine before refueling. Fire, open flame and smoking prohibited. On (Run) Plus ; Positive polarity Off (Stop) Battery Engine oil Engine start (Electric start) ESPAÑOL Add oil COMPONENTS (See Fig. 1) NOTE Please refer to the illustrations on the back page of the front cover or back cover for Fig.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ5 PRE-OPERATION FOR STARTING (See Fig. 2) t Explanation of Fig. 2-t q Oil Gauge e Lower Level pump for the first time. q Check valves w Delivery e Suction w Upper Level Oil capacity (Upper level) : 2. CONNECT SUCTION HOSE w) (See Fig. 2-w Use a reinforced-wall or wire braided hose to prevent suction collapse. Since the pump self-priming time is directly proportional to hose length, a short hose is recommended. y) 5. CHECK FUEL (See Fig.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ6 ENGLISH OPERATING YOUR PUMP 1. STARTING (See Fig. 3) 3. STOPPING (See Fig. 5) (1) Open the fuel cock. (See Fig. 3-q) (1) Set the speed control lever at the low speed (2) Turn the STOP SWITCH to the position “ I ” (ON). (See Fig. 3-w) (3) Set the speed control lever 1/3 of the way towards the high speed position. (See Fig. 3-e) (4) Close the choke lever. (See Fig. 3-r) ■ If the engine is cold or the ambient temperature is low, close the choke lever fully.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ7 Periodic maintenance is vital to the safe and (6) Magneto or electronic ignition system efficient operation of your pump. (7) Spark advance/ retard system, if applicable Check the table below for periodic maintenance (8) Exhaust manifold, if applicable. intervals.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ8 ENGLISH 3. INSPECTING THE SPARK PLUG q) (See Fig. 7-q 5. CLEANING FUEL CUP r) (See Fig. 7-r (1) Clean off carbon deposits on the spark plug electrode using a plug cleaner or wire brush. (2) Check electrode gap. The gap should be 0.6 mm to 0.7 mm (0.02 inch.-0.03 inch.). Adjust the gap, if necessary, by carefully bending the side electrode. Recommended Spark Plug : NGK BR-6HS (CHAMPION RL86C) WARNING Flame Prohibited (1) Inspect fuel cup for water and dirt.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ9 PREPARATIONS FOR STORAGE hole. Severe damage to pump may result if water freezes in the pumping chamber. q) 2. DISCHARGE FUEL(See Fig. 8-q WARNING Replace the fuel hose every 1,000 hours or every Flame Prohibited year. If you do not use the engine more than 1 month, If fuel leaks from fuel hose, replace the fuel hose discharge fuel to prevent gum in the fuel system immediately. and carburetor parts. ■ Retighten loose bolts and nuts.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ10 OIL SENSOR INSTRUCTIONS ENGLISH 1. FUNCTION OF OIL SENSOR The engine will stop automatically when the oil level falls below the safety limit. The engine cannot be started unless the level is raised above How to remove the spark arrester 1. Remove the flange bolts from the muffler cover and remove the muffler cover. 2. Remove the special screw from the spark the prescribed limit. arrester and remove the spark arrester from (See Fig. 2-t) the muffler.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ11 EASY TROUBLESHOOTING Engine dose not start. (See “WHEN ENGINE DOES NOT START”) ■ ■ Is the stop switch at position “ I ” (ON)? ■ Remove and inspect the spark plug. If the electrode is fouled, clean or replace it with new one. ■ Remove the spark plug and connect it to the plug cap. Pull the starter handle while grounding spark plug against engine body. Try with a new spark plug if the spark is weak or there is no spark.
PTX301D ce_PU2365 07.5.14 4:08 PM ページ12 MODEL PTX201D Type PUMP ENGLISH SPECIFICATIONS Self-priming, Diaphragm pump Suction x Delivery Diameters mm (in.) Total Head m (ft) Maximum Delivery Volume Liter(U.S.gal)/min Suction Head ENGINE 50.8 × 50.8 (2×2) 15 (49) 125 (33) 250 (66) 7.6 (25) EX13 EX17 Type Air - Cooled, 4 - cycle, OHC, Gasoline Engine Fuel Automotive unleaded gasoline Fuel Tank Capacity Liter (U.S.gal) 2.7 (0.7) 3.6 (0.
PTX201D PTX301D ISSUE EMD-PU2365 PRINTED IN JAPAN May 2007 9ZZ9990051