- Robin Generator Service Manual

.-.
n
Symptoms
A-3
Starting failure
I
Fuel tank is empty
A-4
Starting failure
I
Water or dust is
mixed with the
fuel
]
Fuel flows only a little, or does not
Breather pipe (in
the tank handle)
Clogging of pipe
Fuel tank, carbure-
Fuel tank is empty
Cock is closed
Water or dust is
mixed with the
Air stays in the
-7
Check the fuel
I
Check breather
pipe
check fuel strainer
Check the fuel pipe
-J
Confirm condi-
tion of the cock
Checking
method
Checking
criteria
Confirm fuel
In case the fuel
tank is empty,
supply fuel.
In case of pipe
clogging, clean it.
In case the fuel
path is clogged,
clean or replace it.
In case water or
dust is mixed with
the fuel, take the
contaminatnt away
or replace the fuel.
In case the air stays
in the pipe, let it
In case the cock is
closed, open it.
out.
Let air into the
strainer cock
El
Remedies
r-
1
Clean or replace
the fuel strainer