- Robin Generator Service Manual

5-3-4 DUAL VOLTAGE TYPE (RGX240D)
The dual voltage t)-pe can generate two Foltages from a sin-
gle generator. It comes in two varieties: 12OV~‘11OV and
1 lOV!ZOV. The circuit is shown in Fig. 5-l 8.
Each of MC1 and MC2 generates an AC 12OV (or 1lOV)
with
the
same phase, which is one half the rated output
voltage. This model has two receptacles to output one half
of the rated voltage from each of the receptacles (112OV or
1 lOV,.
MC1 and MC2 are connected in series to each other so that
the rated voltage (21OV or 21OVj can be obtained from the
receptacles. (See Fig. 5 - 19 .)
I
Fig. 5- 78
240 (22O)V
Fig. 5- 19
5-4 CHANGE of ENGINE PARTS
For details of the engine. please refer to the EYZO service manual. The RGS Series ?mplgs engine parts specia! to the
RGX to suit the modified engine. The engine parts can be classified b>- ignition system.
control system. fuel system. and
cooling system. The engine parts fur each of these systems are explained belox.
5-4-l IGNITION SYSTEM
RGX Series employs a solid state ignition system (T.I.C.). Please rcfcr to the section on Robin Solid State Ignition Engine in
the EYl5. EYlO Service Manual.
All models use a primary exciting coil of especial performance and lead length.
NOTE: Be careful not to use an excitingcoil of different performance because itcan damage the automatic voltage regulator.
- 22 -