ISSUE EMD-GU7220 PRINTED IN JAPAN June 2011 3ZZ9990578 SUBARU Generator
(CPSC 16 CFR Part 1407) (California Proposition 65) DANGER WARNING : Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open. The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Only use OUTSIDE and far away from windows, doors, and vents.
Thank you very much for purchasing a SUBARU GENERATOR. This manual covers operation and maintenance of the SUBARU GENERATOR. This SUBARU GENERATOR can be used for general electrical equipments, appliances, lamps, tools as an AC power source. With regards to DC application, the terminals are used only for charging 12 volt battery. Never use this generator for any other purposes.
ENGLISH FRANÇAISE ESPAÑOL RGX7500 us_GU7220.
① ⑨ ⑦ ENGLISH RGX6500, RGX7500 RGX2900, RGX3600, RGX4800 ② ③ ④ ③ ⑦ ⑥ ② FRANÇAISE ⑥ ⑤ ⑤ ① ⑩ ④ ⑩ ⑨ ⑧ ① ② ④ ⑦ RGX7500 us_GU7220.
ENGLISH 1. SAFETY PRECAUTIONS Please make sure you review each precaution carefully. Pay special attention to statement preceded by the following words. DANGER “DANGER” indicates a possibility of death or serious injury if instructions are not followed. WARNING “WARNING” indicates a strong possibility of severe personal injury or loss of life if instructions are not followed. CAUTION “CAUTION” indicates a possibility of personal injury or equipment damage if instructions are not followed.
WARNING Be extremely careful that all necessary electrical grounding procedures are followed during each and every use. Failure to do so can be fatal. ENGLISH WARNING If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it with water. WARNING Do not contact the generator to a commercial power line. Connection to a commercial power line may short circuit the generator and ruin it or cause electric shock hazard.
2. SPECIFICATIONS ENGLISH MODEL RGX2900 Type RGX3600 RGX4800 RGX6500 RGX7500 Brush-less, self-exciting, 2-poles, single phase Brush, self-exciting, 2-poles, single phase Condenser type AVR type Voltage regulating system FRANÇAISE Generator AC Output Rated voltage-Frequency V-Hz Rated current A 120-60 20.0 24.1/12.0 34.1/17.0 120/240-60 41.7/20.8 50/ 25 Rated output VA (W) 2400 2900 4100 5000 6000 Maximum output VA (W) 2900 3600 4800 6500 7500 Rated power factor 1.
3. COMPONENTS ENGLISH RGX2900, RGX3600, RGX4800 Fuel gauge Tank cap Fuel strainer (Fuel valve) Recoil starter handle Engine switch FRANÇAISE Control panel Recoil starter Oil gauge (oil filler) Fuel tank Spark plug cap ESPAÑOL Oil drain plug Choke lever Air cleaner Muffler cover Exhaust outlet -4- RGX7500 us_GU7220.
ENGLISH RGX6500, RGX7500 Fuel gauge Tank cap FRANÇAISE Control panel Fuel strainer (Fuel valve) Engine switch Recoil starter handle Oil gauge (oil filler) Recoil starter ESPAÑOL Oil drain plug Fuel tank Choke lever Spark plug cap Air cleaner Muffler cover Exhaust outlet -5- RGX7500 us_GU7220.
ENGLISH CONTROL PANEL RGX2900, RGX3600, RGX4800 (RGX4800) (w/Starter motor) Key switch AC receptacle 20A Pilot lamp FRANÇAISE AC receptacle 30A AC receptacle 30A Full power switch Hour meter Engine switch AC circuit breaker DC circuit breaker AC breaker Idel control switch (RGX2900) Earth (ground ) terminal ESPAÑOL DC output terminal (RGX3600) Pilot lamp AC receptacle Hour meter 20A AC receptacle 20A AC AC receptacle 30A receptacle 30A Full power switch Pilot lamp Hour meter AC circuit br
ENGLISH RGX6500, RGX7500 (RGX6500, 7500 w/Starter motor) Key switch FRANÇAISE Idel control switch Full power Pilot lamp switch Hour meter Engine switch ESPAÑOL AC receptacle 30A AC circuit breaker DC circuit breaker AC receptacle 20A DC output terminal Earth (ground) AC receptacle terminal 30A -7- RGX7500 us_GU7220.
4. PRE-OPERATION CHECKS Before checking or refilling oil, be sure generator is located on stable and level surface with engine stopped. ENGLISH CHECK ENGINE OIL Oil filler cap (Oil gauge) ■ Remove oil filler cap and check the engine oil level. ■ If oil level is below the lower level line, refill with suitable oil (see table) to upper level line. Do not screw in the oil filler cap when checking oil level. Upper level Lower level FRANÇAISE ■ Change oil if contaminated. (See "How-To" Maintenance.
ENGLISH CHECK ENGINE FUEL. WARNING ■ Do not refuel while smoking or near open flame or other such potential fire hazards. Otherwise fire accident may occur. FRANÇAISE NOTE : THIS ENGINE IS CERTIFIED TO OPERATE ON AUTOMOTIVE UNLEADED GASOLINE. ■ Check Fuel filter screen Fuel tank cap fuel level at fuel level gauge. ■ If fuel level is low, refill with unleaded automotive gasoline. ■ Stop the engine and open the cap. ■ Close the fuel valve before filling the fuel tank.
ENGLISH CHECKING COMPONENT PARTS Check following items before starting engine: ■ Fuel leakage from fuel hose, etc. ■ Bolts and nuts for looseness. ■ Components ■ Generator for damage or breakage. not resting on or against any adjacent wiring. CHECK GENERATOR SURROUNDINGS Make sure you review each warning in order to prevent fire hazard. ■ Keep area clear of in flammables or other hazardous materials. ■ Keep generator at least 3 feet (1 meter) away from buildings or other structures.
ENGLISH WARNING Death, personal injury and/or property damage may occur unless instructions are followed carefully. ■ Use battery of recommended capacity. ■ Turn the starter switch to the “STOP” position when mounting or FRANÇAISE dismounting battery. When mounting battery, connect the positive (+) cable first and then the negative (-) cable to the battery. Be careful not to short battery cables. When dismounting battery, disconnect negative (-) cable first.
5. OPERATING PROCEDURES ENGLISH STARTING THE GENERATOR [CAUTION] Check the oil level before each operations as outlined by the article "CHECK ENGINE OIL" (a) Turn the Engine switch to the position "ON". OFF (b) Turn the AC circuit breaker to the position "OFF". ON ON OFF OFF (c) Open the fuel valve. CLOSE ESPAÑOL FRANÇAISE ON CLOSE OPEN (d) Set choke lever to close if the engine is cold. Choke lever CLOSE OPEN - 12 - RGX7500 us_GU7220.
ENGLISH (e) Pull the starter handle slowly until passing the compression point (resistance will be felt), then return the handle to its original position and pull briskly. ly isk r ll b Pu ■ If FRANÇAISE the engine fails to start after several attempts, repeat above procedures with choke lever returned to "OPEN" position. ■ Do not fully pull out the rope. ■ After starting, allow the starter handle to return to its original position while still holding the handle.
ENGLISH USING ELECTRIC POWER WARNING ■ Make sure that the appliance is switched OFF before connecting it to the generator. ■ Do not move the generator while it is running. ■ Be sure to ground the generator if the connected appliance is FRANÇAISE grounded. Failure to ground unit may lead to electrical shock. (1) AC APPLICATION (a) Make sure the pilot lamp is turned on. ESPAÑOL (b) Turn off the switch (es) of the electrical appliance (s) before connecting to the generator.
FRANÇAISE ENGLISH Style Ampere Receptacle AC plug Description up to 20A NEMA 5-20R NEMA 5-20P GFCI (Ground Fault Circuit Interrupter) Receptacle, duplex(REC1) up to 20A NEMA L14-20R NEMA L14-20P Locking Receptacle(REC2) up to 30A NEMA L5-30R NEMA L5-30P Locking Receptacle(REC3) up to 30A NEMA L14-30R NEMA L14-30P Locking Receptacle(REC4) TABLE 1 WARNING TWIST ESPAÑOL ■ To take power out from the TWIST LOCK RECEPTACLE, insert the plug into the receptacle, and turn it clockwise to t
ON ON OFF OFF ENGLISH (d) Check and confirm whether circuit breaker position is “ ON ”. (e) Turn on the switch of the appliance. ON After starting the engine, check the GFCI for proper functioning by the following test procedure. ■ Push blue TEST button, The red RESET button will pop out exposing the word TRIP. Power is now off at the outlets protected by the GFCI, indicating that the device is functioning properly.
ENGLISH FULL POWER SWITCH (Except RGX2900) Select the voltage using the FULL POWER SWITCH in accordance with the electrical appliance. Refer to TABLE 2. 120V 120V 240V FRANÇAISE [CAUTION] Change the FULL POWER SWITCH after turning the AC circuit breaker to “OFF”. Switch position Lower Voltage Receptacle Higher Voltage Receptacle 120V Activated full rated output N.A 120/240V Activated half of rated output Activated full rated output ESPAÑOL TABLE 2 - 17 - RGX7500 us_GU7220.
IDLE CONTROL SWITCH automatically reduces engine speed when load is OFF, and automatically increases engine speed to rated r.p.m. when load is ON. IDLE CONTROL SWITCH provides fuel economy and low noise operation at no-load running. ENGLISH IDLE CONTROL SWITCH (Except RGX2900) (1) HOW TO USE IDLE CONTROL SWITCH ■ Start the engine with IDLE CONTROL SWITCH off. ON ■ Turn IDLE CONTROL SWITCH on. FRANÇAISE NOTE : Warm up the engine without a load for a few minutes.
ENGLISH (2) DC APPLICATION The DC terminal is used only for charging 12 volt batteries. It provides up to 12V-8.3A (100W) of maximum power. Red Black - + CONNECTION OF CABLE : FRANÇAISE ■ Connect positive (red) terminal on generator to positive (+) terminal on battery. ■ Connect negative (black) terminal on generator to negative (-) terminal on battery. ■ Both AC and DC output can be used at the same time if the total output is within rated output of the generator.
ON ON OFF OFF (a) Turn off the power switch of the electric equipment and unplug the cord from receptacle of the generator. ENGLISH STOPPING THE GENERATOR (b) Turn the AC circuit breaker to the “OFF” position. ON FRANÇAISE (c) Allow the engine about 3 minutes to cool down at no-load before stopping. OFF (d) Turn the Engine switch to the position “OFF”. CLOSE (e) Close the fuel valve.
ENGLISH 6.WATTAGE INFORMATION Some appliances need a “surge” of energy when starting. This means that the amount of electrical power needed to start the appliance may exceed the amount needed to maintain its use. Electrical appliances and tools normally come with a label indicating voltage, cycles / Hz, amperage (amps) and electrical power needed to run the appliance or tool. Check with your nearest dealer or service center with questions regarding power surge of certain appliances or power tools.
When a long electric extension cord is used to connect an appliance or tool to the generator, a certain amount of voltage drop or loss occurs in the extension cord which reduces the effective voltage available for the appliance or tool. ENGLISH VOLTAGE DROP IN ELECTRIC EXTENSION CORDS Nominal cross section A.W.G. Allowable current mm2 No. A No./mm Ω /100m 1A 3A 5A 8A 10A 12A 15A 0.75 18 7 30/0.18 2.477 2.5V 8V 12.5V ─ ─ ─ ─ 1.27 16 12 50/0.16 1.486 1.5V 5V 7.
ENGLISH 7. SPARK ARRESTER In a dry or wooded area, it is recommendable to use the product with a spark arrester. Some areas require the use of a spark arrester. Please check your local laws and regulations before operating your product. The spark arrester must be cleaned regularly to keep it functioning as designed.
MAINTENANCE, REPLACEMENT, OR REPAIR OF THE EMISSION CONTROL DEVICES AND SYSTEMS MAY BE PERFORMED BY ANY NONROAD ENGINE REPAIR ESTABLISHMENT OR INDIVIDUAL. DAILY INSPECTION ENGLISH 8.
ESPAÑOL FRANÇAISE ENGLISH Periodic Maintenance Schedule table Every 8 hours (Daily) Maintenance Items Clean generator and check bolt and nuts ● (Daily) Check for leakage from hoses and fitting ● (Daily) Check and refill engine oil ● (Refill daily up to upper level) Change engine oil (*Note1) ● (Initial 20 hours) Every 50 hours (Weekly) Every 200 hours (Monthly) Every 500 hours Every 1000 hours ● (Every 100 hours) Clean spark plug ● (Every 100 hours) Clean air cleaner ● ● (Every 100 hour
9. ”HOW-TO” MAINTENANCE ENGLISH ENGINE OIL CHANGE ■ Change engine oil every 100 hours. (For new engine, change oil after 20 hours.) (a) Drain oil by removing the drain plug and the oil filler cap while the engine is warm. Oil drain plug ■ Use fresh and high quality lubricating oil to the specified level as directed on page 6. If contaminated or deteriorated oil is used or the quantity of the engine oil is not sufficient, the engine damage will result and its life will be greatly shortened.
ENGLISH CLEANING AND ADJUSTING SPARK PLUG (a) If the plug is contaminated with carbon, remove it using a plug cleaner or wire brush. (b) Adjust the electrode gap to 0.6 to 0.7 mm (0.024 to 0.028 in.). Gap 0.6 to 0.7 mm (0.024 to 0.028 in.) FRANÇAISE Spark plug : BR-6HS (NGK) CLEANING FUEL STRAINER Dirt and water in the fuel are removed by the fuel strainer. (a) Remove the strainer cup and throw away water and dirt. ESPAÑOL (b) Clean the screen and strainer cup with gasoline.
If the brush become excessively worn, its contact pressure with the slip ring changes and causes a roughened surface on the slip ring, resulting in irregular generator performance. Check the brush every 500 hours or if generator performance is irregular. ENGLISH CHECKING CARBON BRUSH (RGX6500, 7500) BRUSH HOLDER 0.6 to 0.2 in. (15 to 5 mm) BRUSH HOLDER (a) Remove the brush cover. FRANÇAISE BRUSH If the brush is 5 mm long or less, replace it with a new one.
ENGLISH 10. PREPARATION FOR STORAGE The following procedures should be followed prior to storage of your generator for periods of 6 months or longer. ■ Drain fuel from fuel tank carefully by disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making enginestarting difficult. Drain screw FRANÇAISE ■ Remove the carburetor float chamber and also drain the carburetor. ■ Change engine oil. ■ Check for loose bolts and screws, tighten them if necessary.
When generator engine fails to start after several attempts, or if no electricity is available at the output socket, check the following chart. If your generator still fails to start or generate electricity, contact your nearest SUBARU Industrial Power Products dealer or service shop for further information or corrective procedures. ENGLISH 11. TROUBLESHOOTING Set the choke lever to “CLOSE” position. Check if fuel valve is open. If closed, open fuel valve. Check fuel level.
12. WIRING DIAGRAM ENGLISH RGX2900 (60Hz-120V) ENGINE CONT.
ENGINE CONT.
Oil sensor Spark plug Wiring color code Blk : Black Blk/W : Black/White Blu : Blue LBlu : Light Blue Brn : Brown Brn/W : Brown/White Grn : Green Grn/W : Green/White LGrn : Light Green Org : Orange Gry : Gray R : Red W : White Y : Yellow EXC CHC IG COIL W Blk Idle control switch REC4 30A Engine switch W W ENGINE FRANÇAISE Oil sensor control UN Idle solenoid ENGLISH RGX6500,7500 (60Hz-120/240V) Blk Grn Gry REC3 30A LBlu Blu W W Gry Earth (Ground) terminal W DC output terminal 㸫 㸩 AVR
RGX7500 us_GU7220.indd 34 R MAIN Coil 1 W MAIN Coil 2 Brn Brn Grn AVR UN Brn/W Org DC circuit breaker (10A) Pilot PL lamp AC circuit breaker Y Y Org W LGreen Brn W Blu Hour Hr meter Blk REC1 20A DC output terminal Blu Grn ESPAÑOL 㸫 㸩 Full power switch Blk W W REC1 20A CON.
RGX7500 us_GU7220.