Periodic Maintenance Schedule table
Maintenance Items
Every
8 hours
(Daily)
Every
50 hours
(Weekly)
Every
200 hours
(Monthly)
Every
500 hours
Every
1000 hours
Clean generator and check bolt and nuts
● (Daily)
Check for leakage from hoses and fi tting
● (Daily)
Check and refi ll engine oil
●
(Refi ll daily up to upper level)
Change engine oil (*Note1)
●
(Initial 20 hours)
●
(Every 100 hours)
Clean spark plug
●
(Every 100 hours)
Clean air cleaner
●
Clean spark arrester
●
(Every 100 hours)
Replace air cleaner element
●
Clean fuel fi lter
●
Clean and adjust spark plug and electrodes
●
Replace spark plug
●
Remove carbon from cylinder head (*Note 2)
●
Check and adjust valve clearance (*Note 2)
●
Clean and adjust carburetor (*Note 2)
●
Clean and replace carbon brushes
●
Replace fuel lines
●
(Every 2 years)
Overhaul engine (*Note 2)
●
Check AC receptacles
● (Daily)
Check DC termianl
● (Daily)
Check engine switch
● (Daily)
Check rotor
●
Check stator
●
Replace engine mount
●
*Note: 1. Initial oil change should be performed after first twenty (20) hours of operation.
Thereafter change oil every hundred (100) hours.
Before changing oil, check for a suitable way to dispose of old oil.
Do not pour it down into sewage drains, onto garden soil or into open streams.
Your local zoning or environmental regulations will give you more detailed instructions on proper disposal.
*Note: 2. As to the procedures for these items, please refer to the SERVICE MANUAL or consult your nearest
service dealer.