MODEL 3ZZ9990154
3 5 7 5 1 4 2 1 3 5 6 6 8 9 1 10 11 1 1 12 STOP RUN 16 CHOKE 7 14 15 1 2 2 13 6 2 4 1 3 1 3 1 1 3 3 4 2 1 2 2 4 2 5 2 1 1 2 1 3 2 1 STOP 3 2 1 4 RUN 4 2 2 2 STOP 6 CHOKE 1 RUN 1 1 3 1 CHOKE
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ01 WARNING : The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. NOTICE FEDERAL EMISSION COMPONENT DEFECT WARRANTY and CALIFORNIA EMISSION CONTROL WARRANTY are applicable to only those engines/ generators complied with EPA (Environmental Protection Agency) and CARB (California Air Resources Board) emission regulations in the U.S.A.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ02 FEDERAL EMISSIONS COMPONENT DEFECT WARRANTY EMISSIONS COMPONENT DEFECT WARRANTY COVERAGE – This emission warranty is applicable in all States, except the state of California. Fuji Heavy Industries Ltd. and Robin America Inc.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ03 CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The California Air Resources Board and Fuji Heavy Industries Ltd. (herein “FUJI”) are pleased to explain the emission control system warranty on your 2005 and later Small Off-Road engine (herein "engine"). In California, the engine must be designed, built and equipped to meet the State's stringent anti-smog standards.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ04 When warranty repair is needed, the engine must be brought to an authorized service dealer or warranty station’s place of business during normal business hours. In all cases, a reasonable time, not to exceed 30 days, must be allowed for the warranty repair to be completed after the engine is received by the authorized service dealer or warranty station. G.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ1 FOREWORD Thank you very much for purchasing a ROBIN GENERATOR. This manual covers operation and maintenance of the ROBIN GENERATOR. Please take a moment to familiarize yourself with the proper operation and maintenance procedures in order to maximize the safe and efficient use of this product. Keep this owner’s manual at hand, so that you can refer to it at any time.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ2 1. SAFETY PRECAUTIONS Please make sure you review each precaution carefully. Pay special attention to statement preceded by the following words. WARNING “WARNING” indicates a strong possibility of severe personal injury or loss of life if instructions are not followed. CAUTION “CAUTION” indicates a possibility of personal injury or equipment damage if instructions are not followed.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ3 WARNING Do not operate in rain, in wet or damp conditions, or with wet hands. The operator may suffer severe electric shock if the generator is wet due to rain or snow. WARNING If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it with water. WARNING Be extremely careful that all necessary electrical grounding procedures are followed during each and every use. Failure to do so can be fatal.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ4 Symbols and Meanings In accordance with the European requirements (eec Directives),the specified symbols as shown in the following table are used for the products and this instruction manual. Read the operator's instruction manual. Fire, open light and smoking prohibited. Stay clear of the hot surface. Caution, risk of electric shock. Exhaust gas is poisonous. Do not operate in an unventilated room. Do not connect the generator to the commercial power lines.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ5 2. COMPONENTS (See Fig. 1) NOTE Please refer to the illustrations on the back page of the front cover or back cover for Fig. 1 to 6 indicated in the sentence.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ6 4. CHECK GENERATOR SURROUNDINGS. WARNING ■ Make sure you review each warning in order to prevent fire hazard. ■ ■ ■ ■ US ■ GB ■ GB ■ GB GB Keep area clear of in flammables or other hazardous materials. Keep generator at least 3 feet (1 meter) away from buildings or other structures. Only operate generator in a dry, well ventilated area. Keep exhaust pipe clear of foreign objects. Keep generator away from open flame.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ7 (f) After 20 to 30 seconds of warm-up is completed, turn the engine switch to " " (RUN) position. (See Fig. 3-e) q" " (CHOKE) w" " (RUN) NOTE If no generating condition is found out, please consult nearest ROBIN dealer. (g) By changing over the LE display in the multi monitor into the "voltage" indication, make sure the generating voltage is the normal level (approx.120V). 2.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ8 q,w w) (2) AC APPLICATION (See Fig. 4-q (a) Make sure the voltage indicated in the LE display is the normal level (approx. 120V). ■ This generator is thoroughly tested and adjusted in the factory. If the generator does not produce the specified voltage, consult your nearest Robin dealer or service shop. (b) Turn off the switch(es) of the electrical appliance(s) before connecting to the generator.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ9 SAFETY PRECAUTIONS WHILE CHARGING ■ An explosive hydrogen gas is discharged through vent holes in the battery during the charging process. Do not allow spark or open flame around the generator or battery during the charging process. ■ Electrolyte fluid can burn eyes and clothing. Be extremely careful to avoid contact. If injured, wash the affected area immediately with large quantities of water and consult a doctor for treatment.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ10 NOTE The following wattage chart is general guide only. Refer to your specific appliance for correct wattage. To determine the total wattage required to run a particular electrical appliance or tool, multiply the voltage figure of the appliance/tool by the amperage (amps) figure of same. The voltage and amperage (amps) information can be found on a name plate which is normally attached to electrical appliances and tools.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ11 6. SPARK ARRESTER In a dry or wooded area, it is recommendable to use the prodoct with a spark arrester. Some areas require the use of a spark arrester. Please check your local laws and regulations before operating your prodoct. The spark arrester must be cleaned regularly to keep it functioning as designed.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ12 7. MAINTENANCE SCHEDULE MAINTENANCE, REPLACEMENT OR REPAIR OF THE EMISSION CONTROL DEVICES AND SYSTEMS MAY BE PERFORMED BY ANY NONROAD ENGINE REPAIR ESTABLISHMENT OR INDIVIDUAL.
RG2800iS(US)̲GU2010 05.4.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ14 8. "HOW-TO" MAINTENANCE (See Fig. 5) q) L.R R.) (See Fig. 5-q 1. SIDE PANEL (L To access the following items for servicing, take the applicable side cover out by removing the screw with screwdriver or coin. LH-side cover ---- Oil level gauge, Air cleaner, Spark plug, Battery etc. RH-side cover ---- Oil drain screw etc. w) US 2. ENGINE OIL CHANGE (See Fig. 5-w GB GB GB ■ Change engine oil every 50 hours. (For new engine, change oil after 20 hours.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ15 (d) Arrange the wiring so that it won't be damaged by possible vibration caused by the engine. (e) Only after checking that the engine's starter key is in the "OFF" position, securely connect the red cable, to the positive (+) terminal. And then connect the other cable to the negative (-) terminal. Red cable : to the (+) terminal Black cable : to the (-) terminal CAUTION Should the connection be made in incorrect manner, the engine will be broken.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ16 9. PREPARATION FOR STORAGE (See Fig. 6) The following procedures should be followed prior to storage of your generator for periods of 6 months or longer. ■ Drain fuel from fuel tank carefully by disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making engine-starting difficult. ■ Remove the drain screw of the carburetor.(See Fig. 6-q) q DRAIN SCREW US GB GB GB GB GB ■ Change engine oil.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ17 11. SPECIFICATIONS MODEL RG2800iS RG3200iS Inverter Type Frequency Hz 60 V 120 Rated voltage Alternator RG4300iS Maximum output kVA 2.8 3.2 4.3 Rated output kVA 2.5 2.8 3.8 Rated power factor US GB 1.0 GB DC output Over current protector V-A 12 - 8.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ18 12.
RG2800iS(US)̲GU2010 05.4.4 1:35 PM ページ19 RG3200iS / 4300iS (60Hz-120V) [Electric starter model] GENERATOR CONTROL PANEL DC circuit breaker DC output terminal Diode rectifier Coil (1) Diode rectifier Org R Brn/W Coil (2) Brn Grn/Y Brn Grn/Y US Key switch Coil (3) GB MST L.
ISSUE EMD-GU2010 PRINTED IN JAPAN October 2004 CE-SK 000