(3) DC APPLICATION (See Fig.
44
-
ee
)
The DC terminal is used only for charging 12 volt batteries.
It provides up to 12V-8.3A (100W) of maximum power.
q Positive terminal (RED) w Negative terminal (BLACK)
CONNECTION OF CABLE :
Connect positive terminal (red) on generator to positive (+) terminal on battery.
Connect negative terminal (black) on generator to negative (
-
) terminal on battery.
Both AC and DC output can be used at the same time if the total output is within rated output of the
generator.
(d) Turn on the switch of the appliance.
NOTE
When the "O_Lod" (overload) is indicated in the LE display, AC output is cut off on the grounds that the
generator operation is in overload condition or appliance(s) will be out of order.
In this case, stop the engine immediately and check the appliance and/or generator for overloading.
After the check and remedy, restarting the engine will resume displaying in the normal manner.
(2) AC APPLICATION (See Fig.
44
-
qq
,
ww
)
(a) Make sure the voltage indicated in the LE display is the normal level (approx. 120V).
This generator is thoroughly tested and adjusted in the factory.
If the generator does not produce the specified voltage, consult your nearest Robin dealer or service shop.
(b) Turn off the switch(es) of the electrical appliance(s) before connecting to the generator.
(c) Insert the plug(s) of the electrical appliance(s) into the receptacle. (See Fig. 4-q)
Check the amperage of the receptacles
used referring to TABLE 1, and be sure not to take a current
exceeding the specified amperage.
Be sure that the total wattage of all appliances dose not exceed the rated output of the generator.
Up to 20A
Style Ampere
NEMA
5-20R
Receptacle
NEMA
5-20R
AC plug
GFCI (Ground Fault
Circuit Interrupter)
Receptacle, duplex
Up to 30A
NEMA
5-30R
NEMA
5-30R
Locking Receptacle
Description
TABLE 1
To take power out from the TWIST LOCK
RECEPTACLE, insert the plug into the
receptacle, and turn it clockwise to the lock position. (See Fig.
44
-
ww
)
Be sure to ground the generator if the
connected electrical device is grounded.
WARNING