Instructions / Assembly

7
12 V.D.C. ONLY
JUNCTION
BOX
Y
G
BL
R
RED
BLUE
GREEN
YELLOW
BROWN
BR
BK
BLACK
G
BL
R
R
Y
BK
1
2
3
4
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE WATER
HEATER MUST BE REPLACED, IT MUST BE REPLACED WITH 18 GA.,
105°C WIRE OR IT'S EQUIVALENT.
SWITCH
HI-LIMIT T'STAT
MODULE BD.
SPARK CABLE
ELECTRODE
BR
GAS VALVE
LIGHT
( FACTORY WIRING)
( ---- FIELD WIRING)
DISCONNECT POWER SUPPLY BEFORE SERVICING THERMOSTAT
AND HI-LIMIT UNDER ACCESS COVER.
1 3 4 6
CAUTION: DO NOT HI-POT (DIELECTIC HIGH VOLTAGE TEST) THIS
UNIT AFTER INSTALLATION. TO DO SO MAY CAUSE COMPONENT
DAMAGE AND VOIDS WARRANTY OF WATER HEATER.
340461
Figure 5A: D, DE, DEM, DEC MODELS
12 V.D.C. ONLY
JUNCTION
BOX
Y
G
BL
R
RED
BLUE
GREEN
YELLOW
BROWNBR
BK
BLACK
G
BL
R
R
Y
BK
1
2
3
4
SWITCH
HI-LIMIT T'STAT
MODULE BD.
SPARK CABLE
ELECTRODE
BR
GAS VALVE
SWITCH
( FACTORY WIRING)
( ---- FIELD WIRING)
1 3 4 6
340539
LIGHT
RELAY
O
ORANGE
O
(GAS)
(ELECTRIC)
CAUTION: DO NOT HI-POT (DIELECTRIC HIGH VOLTAGE TEST) THIS
UNIT AFTER INSTALLATION. TO DO SO MAY CAUSE COMPONENT
DAMAGE AND VOIDS WARRANTY OF WATER HEATER.
*12VDC SIDE OF RELAY
IF ANY OF THE ORIGI
NAL WIRE AS SUPPLIED WITH THE WATER HEATER
MUST BE REPLACED, IT MUST BE REPLACED WITH 18 GA., 105°C WIRE
OR EQUIVALENT.
DISCONNECT POWER SUPPLY BEFORE SERVICING THERMOSTAT
AND HI-LIMIT UNDER ACCESS COVER.
Figure 5B: DEL, DELC MODELS
Figure 6A: DE, DEM, DEC MODELS
120 V.A.C. ONLY
CODE
BLACK
BK
COLOR
W
WHITE
HI-
LIMIT
T'STAT
BK
BK
BK
SWITCH
BK
W
DISCONNECT POWER SUPPLY BEFORE REMOVING COVER
OPTIONAL
AC POWER
CORD / PLUG
G
G
GREEN
GROUNDING SCREW
ELECTRIC
ELEMENT
340601
SUBURBAN MANUFACTURING COMPANY, DAYTON, TENNESSEE
120 V.A.C SINGLE PHASE - 1440 WATT ELEMENT - 60 CYCLE
TOTAL CONNECTED WATTS = 1440 - AMPS = 12
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE HEATER MUST BE
REPLACED, IT MUST BE REPLACED WITH 14 GA. 105°C WIRE OR IT'S EQUIVALENT.
SI UN DES FILS ELECTIQUES LIVRES AVEC LE CHAUFFE-EAU DOIT ETRE
REMPLACE, UTILISER A CET EFFET UN FIL 14 GA. 105°C OU EQUIVALENT.
Figure 6B : DEL, DELC MODELS
120 V.A.C. ONLY
CODE
BLACK
BK
COLOR
W
WHITE
HI-
LIMIT
T'STAT
BK
BK
BK
SWITCH
BK
W
DISCONNECT POWER SUPPLY BEFORE REMOVING COVER
RELAY
BK
G
G
GREEN
OPTIONAL
AC POWER
CORD / PLUG
*
GROUNDING SCREW
ELECTRIC
ELEMENT
SI UN DES FILS ELECTIQUES LIVRES AVEC LE CHAUFFE-EAU DOIT ETRE
REMPLACE, UTILISER A CET EFFET UN FIL 14 GA. 105°C OU EQUIVALENT.
*120VAC SIDE OF RELAY
340602
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE HEATER MUST BE
REPLACED, IT MUST BE REPLACED WITH 14 GA. 105°C WIRE OR IT'S EQUIVALENT.
SUBURBAN MANUFACTURING COMPANY, DAYTON, TENNESSEE
120 V.A.C SINGLE PHASE - 1440 WATT ELEMENT - 60 CYCLE
TOTAL CONNECTED WATTS = 1440 - AMPS = 12
HOT
COLD
A
CCESS MODULE
B
OARD
JUNCTION BOX
12 V.D.C.
COLD
MOTOR AID
1/2 FEMALE
PIPE FITTING
ACCESS HOLE
GAS SUPPLY
CONTROL HOUSING
HOT
JACKET
JUNCTION BO
X
120 V.A.C.
Figure 7 Figure 8: DEM MODELS ONLY