Instructions / Assembly

9
CORRECT / CORRIGER INCORRECT / INEXACT
BLUE OR BLUE/ORANGE
WELL DEFINED PATTERN
BLEU OU BLEU/ORANGE
TYPE BIEN DEFINI
YELLOW OR YELLOW/ORANGE
ERRATIC PATTERN
JAUNE OU JAUNE/ORANGE
TYPE ERRATIQUE
Figure 13
VENT TERMINAL AIR SUPPLY INLET
X
AREA WHERE TERMINAL IS NOT PERMITTED
A= CLEARANCE ABOVE GRADE,
VERANDA, PORCH, DECK, OR
BALCONY
12 INCHES (30cm) 12 INCHES (30cm)
J= CLEARANCE TO NONMECHANICAL
AIR SUPPLY INLET TO BUILDING
OR THE COMBUSTION AIR INLET
TO ANY OTHER APPLIANCE.
CANADIAN INSTALLATIONS US INSTALLATIONS
1 2
12 INCHES (30cm) 4 FEET (1.2m) BELOW OR TO SIDE
OF OPENING; 1 FEET (300mm)
ABOVE OPENING
B= CLEARANCE TO WINDOW OR
DOOR THAT MAY BE OPENED
12 INCHES (30cm)
CANADIAN INSTALLATIONS US INSTALLATIONS
1 2
9 INCHES (23cm)
K= CLEARANCE TO A MECHANICAL
AIR SUPPLY INLET
6 FEET (1.83m) 3 FEET (91cm) ABOVE IF WITHIN
10 FEET (3m) HORIZONTALLY
C= CLEARANCE TO PERMANENTLY
CLOSED WINDOW
*
*
L= CLEARANCE ABOVE PAVED
SIDEWALK OR PAVED DRIVEWAY
LOCATED ON PUBLIC PROPERTY
7 FEET (2.13m)
*
D= VERTICAL CLEARANCE TO
VENTILATED SOFFIT LOCATED
ABOVE THE TERMINAL WITHIN A
HORIZONTAL DISTANCE OF 2 FT
(61cm) FROM THE CENTER LINE
OF THE TERMINAL
* *
M= CLEARANCE UNDER VERANDA,
PORCH, DECK, OR BALCONY
12 INCHES (30cm)
*
E= CLEARANCE TO UNVENTILATED SOFFIT
*
*
F= CLEARANCE TO OUTSIDE CORNER
*
*
G= CLEARANCE TO INSIDE CORNER
*
*
H= CLEARANCE TO EACH SIDE OF
CENTER LINE EXTENDED ABOVE
METER / REGULATOR ASSEMBLY
3 FEET (91cm) WITHIN A HEIGHT 15 FEET
(4.57m) ABOVE THE METER / REGULATOR
ASSEMBLY
*
I= CLEARANCE TO SERVICE
REGULATOR VENT OUTLET
3 FEET (91cm)
*
1
IN ACCORDANCE WITH THE CURRENT CSA B149.1, NATURAL GAS AND PROPANE INSTALLATION CODE
2
IN ACCORDANCE WITH THE CURRENT ANSI Z223.1/NFPA 54, NATIONAL FUEL GAS CODE
A VENT SHALL NOT TERMINATE DIRECTLY ABOVE A SIDEWALK OR PAVED DRIVEWAY THAT IS LOCATED BETWEEN TWO SINGLE
FAMILY DWELLINGS AND SERVES BOTH DWELLINGS.
PERMITTED ONLY IF VERANDA, PORCH, DECK, OR BALCONY IS FULLY OPEN ON A MINUMUM OF TWO SIDES
BENEATH THE FLOOR.
*
CLEARANCE IN ACCORDANCE WITH LOCAL INSTALLATION CODES AND THE REQUIREMENTS OF THE GAS SUPPLIER.
OPERABLE
FIXED
CLOSED
FIXED
CLOSED
INSIDE
CORNER DETAIL
G
OPERABLE
A
C
F
B
B
B
B
A
J
B
I
H
M
K
E
D
L
B
Figure 14