UC-15I UCG

subzero.com
|
11
TROUBLESHOOTING
Troubleshooting
UNIT OPERATION
Ice machine does not operate.
Verify power is on.
Verify electrical power to ice machine and home circuit
breaker is on.
No light.
LED interior lighting must be replaced by Sub-Zero
factory certied service.
Ice machine operates, but no ice is produced.
Verify connection to water supply.
Verify water lter is not clogged. Replace water lter,
then follow cleaning and sanitizing procedure on page 7.
Verify spray nozzles are not blocked. Follow cleaning and
sanitizing procedure on page 7.
Verify water pressure at 20 psi
(1.4 bar) to 80 psi (5.5 bar).
Verify bin thermostat adjustment, refer to page 5.
Verify ambient air temperature between 50°F
(10°C) and
100°F
(40°C) for indoor model and between 50°F (10°C)
and 110°F
(45°C) for outdoor model.
Unit requires frequent cleaning and sanitizing.
Consult a qualied professional to test water quality and
recommend appropriate water treatment.
Contact Sub-Zero Factory Certied Service to disas-
semble unit and thoroughly clean and sanitize.
ICE PRODUCTION
Low ice production.
Clean condenser area, refer to page 8.
Verify connection to cold water supply.
Verify water lter is not clogged. Replace water lter,
then follow cleaning and sanitizing procedure on page 7.
Verify operation of water inlet valve.
Verify ambient air temperature between 50°F
(10°C) and
100°F
(40°C) for indoor model and between 50°F (10°C)
and 110°F
(45°C) for outdoor model.
Contact Sub-Zero Factory Certied Service if unre-
solved.
Poor ice quality, cubes are shallow, incomplete or white.
Follow cleaning and sanitizing procedure on page 7.
Replace water lter, refer to page 8.
Adjust cube weight, refer to page 5.
Verify water softener is working properly (if applicable).
Consult a qualied professional to test water quality and
recommend appropriate water treatment.
Contact Sub-Zero Factory Certied Service to disas-