Table 3-1: Engine exhaust regeneration lamp sequence
Particulate level Active/Parked regeneration
Inhibit
lamp
Active
regeneration
lamp
Regeneration
needed /
request lamp Engine lamps
Level 0: Passive regeneration
only
Regeneration not needed ON OFF OFF OFF
Regeneration not needed OFF OFF OFF OFF
Level 1: Active regeneration
Active regeneration needed ON OFF SOLID LIGHT OFF
Active regeneration occurring OFF SOLID LIGHT SOLID LIGHT OFF
Level 2: Active / parked
regeneration
Active regeneration needed ON OFF BLINKING LIGHT OFF
Parked regeneration needed ON OFF BLINKING LIGHT OFF
Active regeneration occurring OFF SOLID LIGHT SOLID LIGHT OFF
Parked regeneration occurring OFF SOLID LIGHT SOLID LIGHT OFF
Level 3: De-rating power &
speed
Parked regeneration needed ON OFF BLINKING LIGHT
WARNING
Parked regeneration occurring OFF SOLID LIGHT SOLID LIGHT
WARNING
Level 4: De-rating power &
speed
Parked regeneration needed
(Kubota service)
ON OFF BLINKING LIGHT
WARNING
Parked regeneration occurring
(Kubota service)
OFF SOLID LIGHT SOLID LIGHT
WARNING
Level 5: Engine stop
DPF service required ON OFF BLINKING LIGHT
SHUTDOWN
DPF service required OFF OFF BLINKING LIGHT
SHUTDOWN