Instructions / Assembly

12X
2X (One Spare)
2X
F1000C / F1500C / F2000C
F600C & F700C
PATENT
PENDING
FILTER
SYSTEM
2X
SFS TYPE SWIMMING POOL FILTER SYSTEM
OWNER’S MANUAL FOR ABOVE GROUND
SWIMMING POOLS
IMPORTANT SAFETY INSTRUCTIONS
1. POWER FILTER INSTALLATION
2. PUMP OPERATION
3. FILTER CARTRIDGE CLEANING INSTRUCTIONS
4. USING THE DIVERTER FITTING AND
VACUUM ADAPTER
5. POOL MAINTENANCE
6. POOL WATER CARE
7. TROUBLE SHOOTING GUIDE
8. POWER FILTER DISASSEMBLY AND STORAGE
2
4
5
5
6
7
7
8
8
084-120839 with GFCI - 2013
2
PRELIMINARY STEPS
POWER FILTER
1. READ ALL INSTRUCTIONS CAREFULLY and get a thorough understanding of what is required to
assemble your Type SFS Power Filter.
2. Before you begin to assemble the pool, identify, count, and check all parts needed for assembly.
3. It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets.
1. Installer shall follow written instructions provided for operation of the circulation systems.
2. All electrical components shall be installed in accordance with Article 680 of the National Electrical
Code (NEC) “Swimming Pools, Fountains and Similar Installations” or its latest approved edition.
3. The Filter Cartridge (9) 3-3/4” will hold as many as 2 of the 1” diameter chlorine tablets and the 8” will
hold as many as 6 of the 1” diameter chlorine tablets. Check your chlorine levels to determine the
proper number of chlorine tablets to add. The filter cartridge will automatically dispense chlorine into
the pool as the pump runs. You must have the type of Filter Cartridge (9) with a central core mesh
divider (See page 3) to use the chlorine dispenser. DO NOT use this to dispense powdered chlo-
rine, shock treatment or any other type of chemicals as damage to the pump, filter cartridge, and
pool will occur.
IMPORTANT NOTES:
LIMITED WARRANTY
Polygroup Limited (Macao Commercial Offshore), (hereinafter “Polygroup”) warrants to the original
purchaser only, the SFS type Electric Filter Pump against defects in material and workmanship for 180
days from the date of purchase. Original Purchaser must retain proof of such purchase in the form of an
original store sales receipt and must produce such upon request by Polygroup or its designated agents.
Warranty claims cannot be processed without a valid proof of purchase.
This Limited Warranty applies only to the original purchaser of the product and is limited solely to the
repair or replacement of the product, to be decided in Polygroups sole discretion. Consequential dam-
ages, including claims for loss of water, pool chemicals, damage, or labor are not covered under this
Limited Warranty.
This Warranty will be declared invalid should the Purchaser modify or repair the product themselves or by
unauthorized persons; use non-Polygroup parts or accessories with the product; use the product in
contravention of the Manufacturers Instructions; use improper voltage; abuse the product in any way; or
through accident or negligence. Normal wear-and-tear is not covered under this Warranty, nor are acts of
God outside the control of Polygroup.
IN NO EVENT SHALL POLYGROUP, THEIR AUTHORIZED AGENTS, RELATED ENTITIES, OR EMPLOYEES BE
LIABLE TO THE BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES. Some states or
countries, or others jurisdictions do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
Should you encounter a problem with your Polygroup Product, please do not return the product to the
place or purchase. All Warranty claims must be made directly to Polygroup. Prior to contacting Customer
Service, please first review the Troubleshooting Guide in the Installation Manual, or review the FAQ at
www.polygroup.com . If you are still unable to correct the problem, please contact Polygroup customer
service at (888) 919-0070. Have the product type and your purchase receipt ready. Our Customer Service
Representative will assist you in resolving the problem. You may be asked to return all or part of the
product for inspection and/or repair. Do not return any product to Polygroup without a Return Authori-
zation number.
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
1.
READ AND FOLLOW ALL INSTRUCTIONS
2. WARNING - To reduce the risk of injury, do not permit children to use this
product unless they are closely supervised at all times by an adult who is capable
of assisting a child in distress.
3. WARNING - Risk of electrical shock. Connect only to a grounding type
receptacle. This product is provided with a ground-fault circuit-interrupter.
If replacement of the plug or cord is needed, use only identical replacement parts.
4. WARNING - To reduce the risk of electrical shock, replace damaged cord
(with pump body) immediately. NEVER bury cord. Locate cord to eliminate abuse or
contact from lawn mowers, hedge trimmers, and other equipment. NEVER use an
extension cord to connect unit to electric supply; provide a properly located outlet.
5. CAUTION - The power filter is for use with storable pools only. DO NOT use with
permanently installed pools. A storable pool is constructed so that it may be readily
disassembled for storage and reassembled to its original integrity. A permanently
installed pool is constructed in or on the ground or in a building so that it cannot
be readily disassembled for storage.
6. The unit is provided with a ground-fault circuit-interrupter (GFCI) to interrupt the electrical power flow in
the case of electrical shock. Pushing the TEST button will interrupt the power flow. Pushing the RESET
will restore power. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts
power to the pump without the test button being pushed, a ground current is flowing, indicating the
possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem
corrected by a qualified service representative before using.
7. SAVE THESE INSTRUCTIONS.
Press%
"RESET"%
Button%
To%Start
Pump
Operation
How%to%use%the%GFCI%plug:
*Do%not%connect
%%to%a%timer%device
DISTRIBUTED BY: POLYGROUP LIMITED (MCO)
To order parts, accessories, or answers to frequently asked questions
about your product please visit
WWW.POLYGROUP.COM Customer Service: (888) 919-0070
Avenida Xian Xing Hai, Centro Golden Dragon, 11 Andar M, Macau

Summary of content (4 pages)