Instructions / Assembly

ROTOR REPLACEMENT INSTRUCTION
1. Disassemble the wall fitting and canister like above 7 POWER FILTER DISASSEMBLY AND STORAGE procedure.
2. Detach the motor assembly
3
from canister
9
by turning the counter-clockwise. Be careful not to lose the Motor Seal Gasket
2
.
3. Refer to below motor assembly illustration to replace the Rotor Assembly ,remove the Volute Cover and pull out the Rotor Assembly from the Stator .
Insert new Rotor Assembly into the Stator .
4. Align the Shaft properly and fasten the Volute cover with the Volute Cover Lock Nut or with the Volute Cover Bolt and Nut Set .
5. Attach the Motor Seal
4
to the outlet of Motor Assembly.
6. Slowly insert the motor assembly back into the Canister
9
, so that the Motor Seal
4
is aligned with the outlet port of the Canister
9
. Also please refer to the
motor assembly process "G" in 7 POWER FILTER DISASSEMBLY AND STORAGE.
7. Tighten the Motor Seal Nut
1
by turning the clockwise, be sure the Motor Seal
4
is properly in place.
2
2
2
SFX600/SFX1000
SFX1500
Detaching Motor
Motor Assembly
Motor Assembly
15
OWNER’S MANUAL
Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8 AM to 5 PM Mon. thru Fri.