Installation Instructions and Manual

7
GAS REQUIREMENTS
NOTE: DO NOT use any tape, pipe dope or
threading compound on any flare fiing. This will
cause a clog in the regulator and prevent your grill
from functioning properly.
LIQUID PROPANE TANK REQUIREMENTS
NATURAL GAS REQUIREMENTS
CONNECTING TO THE NG REGULATOR
Turn off the gas at the supply when grill is not
in use.
Please ensure:
Summerset Professional Grills
recommends that only qualified
professionals perform the required
plumbing on this product.
Check the Rating Plate to make sure the
gas supply you are hooking up to is the gas
type the grill is manufactured for.
To ensure satisfactory performance, the gas
supply line must be sized to accommodate
the total BTU requirements of all the gas-
fired equipment that will be connected to
that line.
In no case should pipe less than 1/2” inside
diameter or 1” outside diameter ever be
used to connect this product.
The LP gas tank has a shutoff valve,
terminating in an LP gas supply tank valve
outlet that is compatible with a Type 1 tank
connection device. The LP gas tank must
CONNECTING TO THE LP TANK
Never connect an unregulated LP gas tank to your
gas grill. The gas regulator assembly supplied
with your gas grill is adjusted to have an outlet
pressure of an estimated 11” water column (W.C.)
for connection to an LP gas tank.
The hose and regulator are connected in the
following manner:
Use a standard 20 lbs. LP tank with QCC – 1
fiing
Grills set up for LP gas come equipped
with an LP hose regulator assembly for
connection to a standard 20 lbs. LP cylinder
(Type 1)
NOTE: DO NOT use any tape, pipe dope or
threading compound on any flare fiing. This will
cause a clog in the regulator and prevent your grill
from functioning properly.
Insert the regulator inlet into the cylinder
valve and turn the black coupling nut
clockwise until the coupling nut is
hand tight. DO NOT over-tighten this
connection.
To disconnect the coupling nut, first make
sure the main cylinder valve is turned off.
Grasp the coupling nut and turn counter
clockwise. The inlet will then disengage.
IMPORTANT:
All installation and all installation parts
must conform to local codes with the
National Electrical Code, ANSI Z223.1/
NFPA 70 latest edition and the National
Fuel Gas Code ANSI Z223.1/NFPA 54 in the
U.S. and CGA-B149.1/.2 in Canada
FILLING AND REFILLING LP GAS CYLINDERS
All purging and refilling of LP gas cylinders
must be performed by qualified personnel in
the LP gas industry. Never store a spare LP gas
cylinder under or near this appliance.
Never fill the LP gas cylinder beyond 80 percent
full. Failure to follow these instructions may
result in explosion, personal injury or death.
also have a safety relief device that has a
direct communication with the vapor space
of the tank.
The tank supply system must be arranged
for vapor withdrawal.
The LP gas tank used must have a collar to
protect the tank valve.