Use & Care

Page 8
5.
Before proceeding further, verify that the power supply is disconnected. Verify
that the appropriate electrical supply requirements have been met. Please refer
to the table on page 4 for appropriate electrical requirements. The cooktop is
supplied with a 48-inch long conduit for a connection to an accessible junction
box. The conduit consists of three insulated wires. There are two hot lead
conductors (black and red insulated-tinned copper) and one insulated ground
conductor (green insulated-tinned copper). (See Wiring Diagram for model
CR424 below and on bottom of cooktop.)
Electrical Connection
Attach conductor wires to residence wiring in accordance with national, state and
local electric codes.
Warning Grounding
The entire appliance must be grounded at all times
when the electrical power supply is on. Do not
ground the appliance with the neutral house supply
wire (white). A separate ground must be used.
!
Wiring Diagram