Instruction Manual

7
ELECTRICAL CONNECTION
The electrical connection must be performed by a qualified technician. The connection must comply
with all local, state and national standards and regulations.
Electrical Requirements
Power supply
input
Circuit
breaker
Minimum
wire size
Conduit
size
200-240 V AC
50/60 Hz
15 Amp
16 AWG
¾”
You can find the identification plate with the electrical specifications on the underside of the
appliance
Identification
plate
Connect Electrical Supply
WARNING: Disconnect power before servicing.
The electrical power supply should be a 1-phase, 3-wire system with ground connection. Install
suitable junction box (not furnished). Connect the flexible cable conduit from the cooktop to the
junction box using a UL listed or CSA approved conduit connector.
Connect the cooktop lead wires to the junction box supply wires in proper phase:
Black (L1) to black
Red (L2) to red
Green (ground) to ground.
WARNING: Always connect the ground wire.