Instruction Manual
7
ELECTRICAL CONNECTION
The electrical connection must be performed by a qualified technician. The connection must comply
with all local, state and national standards and regulations.
Electrical Requirements
Model
Power supply
input
Circuit
breaker
Minimum
wire size
Conduit
size
CREK2B
CREK2W
200-240 V AC
50/60 Hz
15 Amp
16 AWG
¾”
You can find the identification plate with the electrical specifications on the underside of the
appliance
Identification
plate
Connect Electrical Supply
WARNING: Disconnect power before servicing.
The electrical power supply should be a 1-phase, 3-wire system with ground connection. Install
suitable junction box (not furnished). Connect the flexible cable conduit from the cooktop to the
junction box using a UL listed or CSA approved conduit connector.
Connect the cooktop lead wires to the junction box supply wires in proper phase:
Black (L1) to black
Red (L2) to red
Green (ground) to ground.
WARNING: Always connect the ground wire.