CONVERSIONS
CAUTION: Shut off the gas supply prior to disconnecting the electrical power, before proceeding
with the conversion.
Replacing Nozzles
The burners can be adapted to suit different types of gas by fitting the nozzles that correspond to
the gas used. To do this, it is necessary to remove the burner heads and use a straight key "B"
to unscrew the nozzle "A" (see Fig. 7) and replace it with a nozzle corresponding to the gas
used.
Be sure the nozzle is seated tightly.
After making these replacements, the technician must regulate the burners as described in the
Adjustmentssection on the previous page, and apply the label corresponding to the new gas
type in place of that previously applied. This label is contained in the spare nozzle bag.
Fig. 7
Adjust the Pressure Regulator
The gas regulator was set up to Natural Gas. To convert to Propane Gas:
1. Unscrew the aluminum cap
2. Remove and turn the plastic pin 180°
3. Screw in the plastic pin
4. Screw in the aluminum cap
To make it easier for the fitter, we have prepared a table indicating the flow capacities, the heat
capacities of the burners, the diameter of the nozzles and the working pressure for the various types
of gas.
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer’s instructions and all applicable codes and requirements of the authority having
jurisdiction. In the information in these instructions is not followed exactly, a fire, explosion or
production of carbon monoxide may result causing property damage, personal injury or loss of
life. The qualified service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted appliance is checked
as specified in the manufacturer’s instructions supplied with the kit.