Use & Care

Item No. 0AH-00-001 Revised: 07/24/12
EZ-Vent INSTALLATION
INSTRUCTIONS
Models: 1600 Series
Below are four types of ventilation options available with the 1600 series range hoods.
7” Round, Vertical Discharge
Knock-out both top openings. Mount the duct work to the 7”
round discharge recessed into the top of the hood. Be cautious
not to block the fan or damper blades with screws. Remove the
charcoal filter pad, baffle plate, and 3”x10” damper and discard.
An optional 7” round damper is available (part number 5AH-35-
707).
3 1/4” x 10”, Vertical Discharge (from top of hood)
Knock-out top 3”x10” duct opening near the back. Attach 3”x10”
damper plate on the top of the hood with damper blade opening
to a vertical position. Remove charcoal filter pad and discard.
For best results, seal all seams with duct tape.
3 1/4” x 10”, Horizontal Discharge (from rear of hood)
Knock-out rear 3”x10” duct opening. Attach 3”x10” damper
plate on the back of the hood with damper blade opening to
horizontal position. Remove charcoal filter pad and discard.
For best results, seal all seams with duct tape.
Re-circulating (non-vented / ductless)
The range hood is shipped in this configuration. No
modifications are required.
Remove Phillips head screw holding in the baffle plate and
discard both.
Remove Phillips head screw holding 3”x10” damper plate and
discard both. For best results, seal all seams with duct tape.
** Revision 2/09 Electrical cut-
out is
now located on the opposite side
than shown. While facing the hood
it is now located on the right-side
rear. We no longer provide an
electrical cut-out on the rear.