Do not lay tools or metal objects on top of the
batteries
Use tools with insulated handles
1. Unplug the unit from the wall.
2. Follow the Installation Instructions found on
page 3 of this manual, starting with step 8 and
working back to step 1.
3. Remove and safely dispose of old batteries.
4. Install new batteries per the installation
instructions on page 3.
technIcal SpecIfIcatIonS
Model 100
A.C. Lower Voltage Limit 98 VAC ± 5V
Output Voltage with Full Load 85-135V ± 10V
Maximum Output Current 12 FLA
Battery Lower Voltage Limit 18.5V ± 0.3V
Main Output Frequency 60 Hz
Overload 125 ± 3% (With Auto
Reset Function)
Alarm Contact RJ11 Connection,
Normally Closed Dry
Contact
Auxiliary Inputs 24VDC, 20A max
Reserve Power (total hours of operation)
Duty Cycle (% of time running)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 20 25 30
100
90
80
70
60
50
40
30
20
10
0
Performance curve results using a 3/4 HP pump with
a 7.5 FLA and (2) Metropolitan Power Plus model
31P-36 batteries.
Warranty IS voId If...
1. Power cord has been cut or the grounding
prong has been removed.
2. Unit has been used in an outdoor application.
3. Batteries not meeting the above specications
have been used.
4. Unit has been submerged in water.
5. Unit has been tampered with in any manner
not described in the above instructions.
6. Unit has been disassembled by the customer.
7. Unit has been applied to products exceeding
the maximum capacity of the Unit, i.e., a pump
other than the one supplied with the unit or
more than one pump.
8. Unit has been applied to the wrong voltage.
9. Any labels or cord tags have been removed.