User Manual

9
mWARNING! Keep hose away from sharp objects.
Bursting hoses may cause injury. Examine hoses regularly and
replace if damaged. Do not attempt to mend a damaged hose.
9. Connect the garden hose adapter (female coupler) to
the water inlet of the pressure washer, then thread your
garden hose (male end) into the garden hose adapter
(Fig. 9). The garden hose must have an internal diameter
of at least 13 mm (1/2 in.) and must be reinforced.
The water supply must be at least equal to the washer
delivery capacity.
NOTE: The machine is not suitable for connection to the
potable water main.
10. Attach garden hose to water supply (Fig. 10).
mWARNING! Do not connect to potable water system.
mWARNING! If connection is made to a potable water
system, the system shall be protected against backow.
mWARNING! The intake water temperature must not
exceed 104ºF/40ºC. The water supply must not exceed
0.7 MPa.
mCAUTION! The washer must only be used with clean
water; use of unltered water containing corrosive chemicals
will damage the washer.
Operation
Using the Pressure Washer
mIMPORTANT! This pressure washer is equipped with
a micro-switch sensitive to water ow. This Total Stop System
(TSS) senses water ow in the pump. When the trigger is
released, water stops owing through the pump. The TSS then
automatically turns the motor o to protect the pump from
overheating, thus saving energy and prolonging pump life.
1. Position the washer as CLOSE as possible to the
water supply.
2. The washer must be used on a secure and stable surface
in a standing, upright position (Fig. 11).
3. Make sure the unit is switched o before plugging the unit
into the power outlet.
4. Check that the electrical supply voltage and frequency
(Volt/Hz) correspond to those specied on the rating plate.
If the power supply is correct, you may now plug the
pressure washer into the power outlet (Fig. 12).
R
Fig. 9
Garden hose
This end to
water inlet
Garden hose
(male end)
Water inlet
Fig. 10
Connect to water supply
Garden hose
Fig. 11
RESET
TEST
Fig. 12
GFCI
Reset