User Guide

2-10 Sun Blade T6320 Server Module Service Manual June 2009
FIGURE 2-4 DIMM Locate Button and DIMM LEDs
You can also use TABLE 2-2 to identify the DIMMs you want to remove.
TABLE 2-2 FB-DIMM Configuration and Installation
Branch Name Channel Name FRU Name
Motherboard
FB-DIMM
Connector
FB-DIMM
Installation
Order
*
FB-DIMM
Pair
\
Branch 0 Channel 0 /SYS/MB/CMP0/BR0/CH0/D0 J1001 1 A
/SYS/MB/CMP0/BR0/CH0/D1 J1101 3 B
Channel 1 /SYS/MB/CMP0/BR0/CH1/D0 J1201 2 A
/SYS/MB/CMP0/BR0/CH1/D1 J1301 3 B
Branch 1 Channel 0 /SYS/MB/CMP0/BR1/CH0/D0 J1401 1 C
/SYS/MB/CMP0/BR1/CH0/D1 J1501 3 D
Channel 1 /SYS/MB/CMP0/BR1/CH1/D0 J1601 2 C
/SYS/MB/CMP0/BR1/CH1/D1 J1701 3 D
Branch 2 Channel 0 /SYS/MB/CMP0/BR2/CH0/D0 J2001 1 E
/SYS/MB/CMP0/BR2/CH0/D1 J2101 3 F
Channel 1 /SYS/MB/CMP0/BR2/CH1/D0 J2201 2 E
/SYS/MB/CMP0/BR2/CH1/D1 J2301 3 F
Branch 3 Channel 0 /SYS/MB/CMP0/BR3/CH0/D0 J2401 1 G