User Guide

2-38 Sun Blade T6320 Server Module Service Manual June 2009
2. Type the show /SPfaultmgmt command to obtain additional fault
information.
The fault is captured by ILOM, where the fault is logged. The Service Action
Required LED is lit, and the faulty component is disabled.
For example:
In this example, /SYS/MB/CMP0/BR2/CH1/D1 is disabled. The system can
boot using memory that was not disabled until the faulty component is
replaced.
Note You can use ASR commands to display and control disabled components.
See Section 2.9, “Managing Components With Automatic System Recovery
Commands” on page 2-48.
2.6.4 Clearing POST Detected Faults
In most cases, when POST detects a faulty component, POST logs the fault and
automatically takes the failed component out of operation by placing the component
in the ASR blacklist.
See Section 2.9, “Managing Components With Automatic System Recovery
Commands” on page 2-48).
After the faulty FRU is replaced, you must clear the fault by removing the
component from the ASR blacklist.
ok #.
->
->
show /SP/faultmgmt
/SP/faultmgmt
Targets:
0 (/SYS/MB/CMP0/BR2/CH1/D1)
Properties:
Commands:
cd
show