User manual

3-22 Sun Fire X4100 and Sun Fire X4200 Servers Service Manual June 2006
9. Install the upper cable retainer to the chassis midwall. See FIGURE 3-19:
a. Insert the two pegs on the cable retainer into the two holes in the chassis
midwall.
b. Slide the cable retainer forward until it is locked in place and it is holding the
flex cable connector firmly against the rear of the DVD-ROM drive.
FIGURE 3-19 Installing the Cable Retainer (Sun Fire X4200 server shown)
10. Replace the front cover to the chassis. See FIGURE 3-4.
a. Place the front edge of the cover squarely onto the chassis top-front edge.
b. Set the rear of the cover down so that it fits into the keyed slots on the chassis
sides.
c. Slide the cover toward the rear of the chassis to lock it in place.
Caution Ensure that the front edge of the cover is seated tightly and squarely
against the gasket on the top-front edge of the chassis to avoid overheating the
server.