Storage Subsystems Troubleshooting Guide

Appendix A Virtualization Engine References 129
TABLE A-4 provides service codes for the virtualization engine.
TABLE A-3 Port Communication
Port Port Port Number
Daemon Management Programs 20000
Daemon Daemon 20001
Daemon virtualization engine 25000
virtualization engine virtualization engine 25001
TABLE A-4 Service Codes
Code
Number Cause Corrective Action
005 PCI bus parity error. Replace virtualization engine.
24 The attempt to report one error resulted in
another error.
Cycle power to the virtualization engine.
40 Corrupt database Clear SAN database
Cycle power to the virtualization engine.
Import SAN zone configuration
41 Corrupt database Clear SAN database
Cycle power to the virtualization engine
Import SAN zone configuration
42 Zone mapping database Import SAN zone configuration
050 This message indicates that an attempt to
write a value into non-volatile storage
failed. It could be a hardware failure, or it
could be that one of the databases stored in
Flash memory could not accept the entry
being added.
Clear the SAN database.
Cycle power to the virtualization engine.
051 Cannot erase FLASH memory. Replace virtualization engine.
53 Unauthorized cabling configuration Check cabling. Ensure server/switch
connects to host-side and storage connects
to device side of virtualization engine
virtualization engine.
If necessary, clear SAN database.
If necessary, cycle virtualization engine
power.
If necessary, import SAN zone
configuration.