Server User Manual
Table Of Contents
- Sun Fire™ X2250 Server Service Manual
- Contents
- Preface
- Sun Fire X2250 Server Overview
- Troubleshooting
- Performing Diagnostics
- 3.1 Pc-Check Diagnostics Overview
- 3.2 System Information Menu Options
- 3.3 Advanced Diagnostics Tests Menu Options
- 3.4 Immediate Burn-in Testing
- 3.5 Deferred Burn-in Testing
- 3.6 Create Diagnostic Partition Option
- 3.6.1 Removing Existing Partitions From a Hard Disk
- 3.6.2 Adding a Diagnostic Partition to the First Bootable Disk
- 3.6.3 Creating a Log File on the Diagnostic Partition
- 3.6.4 Accessing the Diagnostic Partition on a Red Hat Linux System
- 3.6.5 Accessing the Diagnostic Partition on the Solaris 10 Operating System
- 3.6.6 Accessing the Diagnostic Partition on the Windows Server 2003 Operating System
- 3.7 Show Results Summary
- 3.8 Print Results Report
- 3.9 About Pc-Check
- 3.10 Exit to DOS
- Maintaining the Sun Fire X2250 Server
- 4.1 Tools and Supplies Needed
- 4.2 Installation Precautions
- 4.3 Powering Off the Server and Removing the Cover
- 4.4 Locations of Server Components
- 4.5 Component Replacement Procedures
- 4.5.1 Replacing the I/O Board
- 4.5.2 Replacing the PCIe Card and Riser Assembly
- 4.5.3 Replacing a Hard Disk Drive and Carrier
- 4.5.4 Replacing an HDD Backplane Assembly
- 4.5.5 Removing and Installing the ODD Drive Assembly
- 4.5.6 Replacing the Air Duct
- 4.5.7 Replacing the Power Supply
- 4.5.8 Replacing the Single Fan Module
- 4.5.9 Replacing the Dual Blower Module
- 4.5.10 Replacing Memory Modules
- 4.5.11 Replacing the System Battery
- 4.5.12 Replacing a CPU and Heatsink
- 4.5.13 Installing a New CPU
- 4.5.14 Replacing Cables
- 4.5.15 Motherboard
- System Specifications
- Using the Tools & Drivers CD
- Installing the Server Into a Rack With Optional Slide Rails
- C.1 Disassembling the Slide Rails Before Installation
- C.2 Installing the Mounting Brackets Onto the Server
- C.3 Attaching the Slide-Rail Assemblies to the Rack
- C.4 Installing the Server Into the Slide-Rail Assemblies
- C.5 Installing the Cable Management Assembly
- C.6 Verifying Operation of the Slide Rails and CMA
- Index

Index-2 Sun Fire X2250 Server Service Manual • February 2010
diagnostics CD, 1-4
DIMMs, see memory modules
driver updates, -xi
dual blower module
replacing, 4-26
DVD drive
location, 1-5
replacing, 4-18
troubleshooting, 2-5
E
environmental specifications, A-3
ESD precautions, 4-2
Ethernet connectors, location, 1-5
external device, troubleshooting, 2-6
F
fans
blower module replacement, 4-26
single fan module replacement, 4-25
fault LED, 1-5
features, 1-2
firmware update
CD, 1-4
firmware updates, -xi
front panel, 1-4
H
hard disk drive
location, 1-5, 1-6, 4-5
replacing, 4-13
troubleshooting, 2-5
HDD, see hard disk drive
height of system, A-1
hung server, troubleshooting, 2-5
I
I/O board
location, 1-6, 4-5
replacing, 4-7
input current, A-2
input frequency, A-2
input voltage range, A-2
installation
ESD precautions, 4-2
postinstallation instructions, 4-3
precautions, 4-2
preinstallation instructions, 4-2
installing to a rack, C-1
Integrated Lights Out Manager, 1-4
Intel PROSET driver software
CD, 1-4
installing, B-11
internal components, 1-6, 4-5
J
Java Enterprise System, 1-3
K
keyboard, troubleshooting, 2-5
M
main power, applying, 1-8
maintenance procedures
ESD precautions, 4-2
postinstallation precautions, 4-3
preinstallation instructions, 4-2
memory
specifications, 1-2
troubleshooting, 2-6
memory modules
population rules, 4-28
replacing, 4-28
slot locations, 1-6, 4-5
motherboard
cable connections, 4-45
mouse, troubleshooting, 2-5
N
network I/O, 1-2
network status indicator, troubleshooting, 2-4
O
operating system software, 1-3
operating system software supported, 1-3
P
PCI-Express card
replacing, 4-9
PCI-Express slots, 1-5
location, 1-6, 4-5










