Server User Manual
Table Of Contents
- Sun Fire™ X2250 Server Service Manual
- Contents
- Preface
- Sun Fire X2250 Server Overview
- Troubleshooting
- Performing Diagnostics
- 3.1 Pc-Check Diagnostics Overview
- 3.2 System Information Menu Options
- 3.3 Advanced Diagnostics Tests Menu Options
- 3.4 Immediate Burn-in Testing
- 3.5 Deferred Burn-in Testing
- 3.6 Create Diagnostic Partition Option
- 3.6.1 Removing Existing Partitions From a Hard Disk
- 3.6.2 Adding a Diagnostic Partition to the First Bootable Disk
- 3.6.3 Creating a Log File on the Diagnostic Partition
- 3.6.4 Accessing the Diagnostic Partition on a Red Hat Linux System
- 3.6.5 Accessing the Diagnostic Partition on the Solaris 10 Operating System
- 3.6.6 Accessing the Diagnostic Partition on the Windows Server 2003 Operating System
- 3.7 Show Results Summary
- 3.8 Print Results Report
- 3.9 About Pc-Check
- 3.10 Exit to DOS
- Maintaining the Sun Fire X2250 Server
- 4.1 Tools and Supplies Needed
- 4.2 Installation Precautions
- 4.3 Powering Off the Server and Removing the Cover
- 4.4 Locations of Server Components
- 4.5 Component Replacement Procedures
- 4.5.1 Replacing the I/O Board
- 4.5.2 Replacing the PCIe Card and Riser Assembly
- 4.5.3 Replacing a Hard Disk Drive and Carrier
- 4.5.4 Replacing an HDD Backplane Assembly
- 4.5.5 Removing and Installing the ODD Drive Assembly
- 4.5.6 Replacing the Air Duct
- 4.5.7 Replacing the Power Supply
- 4.5.8 Replacing the Single Fan Module
- 4.5.9 Replacing the Dual Blower Module
- 4.5.10 Replacing Memory Modules
- 4.5.11 Replacing the System Battery
- 4.5.12 Replacing a CPU and Heatsink
- 4.5.13 Installing a New CPU
- 4.5.14 Replacing Cables
- 4.5.15 Motherboard
- System Specifications
- Using the Tools & Drivers CD
- Installing the Server Into a Rack With Optional Slide Rails
- C.1 Disassembling the Slide Rails Before Installation
- C.2 Installing the Mounting Brackets Onto the Server
- C.3 Attaching the Slide-Rail Assemblies to the Rack
- C.4 Installing the Server Into the Slide-Rail Assemblies
- C.5 Installing the Cable Management Assembly
- C.6 Verifying Operation of the Slide Rails and CMA
- Index

1-8 Sun Fire X2250 Server Service Manual • April 2009
1.4.2 Powering On Main Power Mode
To power on main power for all server components:
1. Verify that the power cord has been connected and that standby power is on.
In standby power mode, the Power/OK LED on the front panel flashes. See
FIGURE 1-1.
2. Use a non-metallic stylus to press and release the recessed Power button on the
server front panel.
When main power is applied to the full server, the Power/OK LED next to the
Power button lights and remains lit.
1.4.3 Shutting Down Main Power Mode
To power off the server from main power mode, use one of the following two
methods:
■ Graceful shutdown: Use a non-metallic stylus to press and release the Power
button on the front panel. This causes Advanced Configuration and Power
Interface (ACPI) enabled operating systems to perform an orderly shutdown of
the operating system. Servers not running ACPI-enabled operating systems will
shut down to standby power mode immediately.
■ Emergency shutdown: Press and hold the Power button for four seconds to force
the main power off and enter standby power mode. When the main power is off,
the Power/OK LED on the front panel will begin flashing, indicating that the
server is in standby power mode.
Caution – To completely power off the server, you must disconnect the AC power cords
from the back panel of the server.