22 Sun Blade X6270 Server Module Installation Guide December 2009
a. Install the top cover.
See “Install Cover on Server” on page 11.
b. Install the server into the rack.
See “Installing and Powering On the Sun Blade X6270 Server Module” on
page 33.
c. Reconnect the power cord (or cords) to the power supply (or supplies) and
power on the server.
See “Installing and Powering On the Sun Blade X6270 Server Module” on
page 33.
Verify that the AC Present LED is lit.
Adding a CompactFlash Module
The Sun Blade X6270 Server Module is not shipped with the compact flash module
option installed. This option must be ordered and is shipped separately for customer
installation.
Refer to the following procedure when adding a compact flash module option to the
Sun Blade X6270 Server Module.
Install CompactFlash Module
1. Remove the cover from the server.
See “Remove Cover From Server” on page 11.
2. Locate the CompactFlash module slot on the motherboard.
Note If a RAID expansion module (REM) is installed, the CompactFlash slot is
located underneath the REM board.
For CompactFlash location on motherboard, see “Sun Blade X6270 Server Module
Option Locations” on page 8.
3. To install the CompactFlash module, do the following:
a. Locate the keys on the side of the compact flash card and align them with the
sides of the CompactFlash slot.
See
FIGURE 2-6.
b. Slide the compact flash card into the slot until it locks into place.