User's Manual

Chapter 4 Setting Up ILOM 47
Logging In to ILOM
This section presents the following procedures:
“Log In to ILOM Using a Serial Connection” on page 47
“Log In to ILOM From an Ethernet Connection Using the CLI” on page 48
Log In to ILOM Using a Serial Connection
1. Verify that your serial console connection to the server module or CMM is
secure and operational.
2. Ensure that the following serial communication settings are configured.
8N1: eight data bits, no parity, one stop bit
9600 baud (default, can be set to any standard rate up to 57600)
Disable hardware flow control (CTS/RTS)
3. Press Enter to establish a connection between your serial console and ILOM.
A login prompt to ILOM appears.
4 Log in to ILOM. Follow instructions in this chapter to log in to ILOM. See
“Logging In to ILOM” on page 47.
5 Configure an IP
address.
Follow the instructions in this chapter to initially configure an
IP address: see “Configuring an IP Address” on page 49.
6 If applicable,
obtain
additional
information
about ILOM.
For more information about configuring or modifying an IP
address in ILOM, refer to the Sun Integrated Lights Out Manager
2.0 Users Guide or the Integrated Lights Out Manager 3.0
Documentation Collection.
TABLE 4-1 IP Address Configuration Tasks (Continued)
Step Requirement Description