Operation Manual
9
Features of your Café Series
®
Espresso Machine continued
Pre-Infusion
Pre-infusion is programmed into the
‘MANUAL’,
single espresso and double
espresso operations. It is a gradual increase
of water pressure pre-soaking the coffee cake
before full water pressure is applied. This in
turn delivers greater body and sweetness to
the espresso.
Anti-Calc Filter
An Anti-Calc water filter reduces impurities
that taint the flavour and odour of the
water, improving the taste and aroma of the
espresso brewed. Additionally, scale build up
is slowed reducing the frequency of cleaning
required.
The Anti-Calc water filter fitted inside the
3 litre water reservoir has a 12 month life
for domestic use and a 3 month life for
commercial use.
Note: Contact Sunbeam on 1800 025
059 for replacement filters (Part code:
EM69101).
Note: The espresso machine can operate
normally without the filter and is easily
removed by gently pulling it out.
Single & Double Pour Spouts
Supplied with the espresso machine are two
pouring spouts – Standard two pour spout
and a single pour spout.
Your espresso machine group handle will
come fitted with the standard two pour spout
for making two coffees simultaneously and
for most coffee makers this is ideal.
However for those regularly making single
cups you may like to remove the two pour
spout and fit the group handle with the
single pour spout. The pour from the single
spout is more defined, evenly transferring
the qualities of the espresso into one cup
preventing loss of any characteristics during
the espresso pour.
The two pour spout is securely fixed to the
group handle using Loctite
™
, so removing the
two pour spout may be difficult and you will
need to use force.
To remove the two pour spout use a piece
of wooden dowel with a 5mm diameter (or
a rigid utensil of the same diameter). Rest
it over the top of the pour spouts and then
using the dowel as leverage turn it anti-
clockwise to loosen the pour spout.
Alternatively, protect the pour spout with a
cloth and two pieces of thin wood on either
side. Gently secure the pour spout in a vice.
Slowly loosen the pour spout from the group
handle.
Once loosened use your hand to completely
remove. Then simply screw on the single pour
spout until it is firmly tightened.