Owner Manual
Operation
OFF
LOW
IGNITOR
OFF
LOW
IGNITOR
OFF
LOW
IGNITOR
HIGH HIGH
HIGH
Figure A Figure B Figure C
P
U
S
H
T
O
T
U
R
N
P
U
S
H
T
O
T
U
R
N
Caution: Do not attempt to operate until you have read and understand all Safety Information in this manual and all
assembly is complete and leak checks have been performed.
Before Turning Gas Supply On:
1. Your re table was designed and approved for outdoor use only. Do NOT use it inside a building, garage, or any other
enclosed area.
2. Make sure surrounding areas are free of combustible materials, gasoline, and other ammable vapors or liquids.
3. Ensure that there is no obstruction to air ventilation. Be sure all gas connections are tight and there are no leaks.
4. Be sure the cylinder cover is clear of debris. Be sure any component removed during assembly or servicing is replaced
and fastened prior to starting.
Before Lighting:
1. Fire table should be thoroughly inspected before each use, and by a qualied service person at least annually.
If relighting a hot re table, always wait at least 5 minutes.
2. Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear. Suspected areas should be leak
tested. If the hose leaks, it must be replaced prior to operation. Only use the replacement hose assembly specied by
manufacturer. The burner must be replaced prior to the appliance being put into operation if it is evident that the burner
is damaged. The replacement burner should be specied by manufacturer.
Lighting:
1. Make sure the control knob is in the “OFF” position (Figure A).
2. Fully open LP cylinder valve.
Note: For initial start or after any cylinder change, hold Control Knob IN for 2 minutes to purge air from gas lines
before proceeding.
3. Push in gas control knob, turn counterclockwise to “LOW” (Figure B), and press the RED Ignitor button to light the re
table. If needed, keep the control knob depressed and continue pressing the RED Ignitor button until the re table lights
(you should hear a clicking sound).
4. After the re table lights, release control knob. To increase the ame, turn the control knob counterclockwise to
“HIGH” (Figure C). To decrease the ame, turn the control knob clockwise to “LOW”.
Note: If burner fails to remain lit, all valves should be closed and a waiting period of at least 5 minutes should pass before
attempting to light.
WARNING
FOR YOUR SAFETY
Be careful when attempting to manually ignite this
re table. Holding in the control knob for more
than 10 seconds before igniting the gas will cause
a ball of ame upon ignition.
Re-lighting:
1. Turn control knob to “OFF”.
2. Repeat the “Lighting” steps on prior page.
Turn off:
1. To extinguish burner depress control knob and continue
to turn it clockwise to “OFF”.
2. Turn cylinder valve clockwise to “OFF” and disconnect
regulator when re table is not in use.
WARNING
FOR YOUR SAFETY
Fire table will be hot after use. Handle with
extreme care.
Page 16