Installation Guide

room temperature for at least one hour.
OPERATION INSTRUCTIONS FOR THE FLUSH FIT
REGISTER BOOSTER
READ AND SAVE THESE INSTRUCTIONS
MODEL: HC500
With the use of any electrical appliance, it is important to observe all basic precautions to minimize the risk associated with use, such as electrical shock, fire, or injury to persons. Read these instructions before using
your Flush Fit Register Booster
.
1. The Flush Fit Register Booster
will be as warm as the air that is delivered from the register of your forced air furnace and/or cooling system. The maximum temperature for the register is 140° Fahrenheit or 60°
Centigrade. Your Flush Fit Register Booster
should never be exposed to higher temperatures or temperatures below freezing.
2. Do not in any way block the air grilles of the Flush Fit Register Booster
. Pressure on the bottom or top grilles of the Flush Fit Register Booster
may cause the fan impeller to contact these grilles and damage the unit.
3. Unplug the Flush Fit Register Booster
when not in use. Turn the unit off before unplugging.
4. Do not operate the Flush Fit Register Booster
with a damaged plug or cord, if the unit malfunctions, becomes noisy when operating, has been dropped or otherwise damaged, or if the housing is damaged or broken.
Discard or return the unit for inspection, replacement, or repair.
5. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances.
Arrange cord away from traffic area and where it will not be tripped over.
6. The Flush Fit Register Booster
should never be exposed to moisture. Do not use the unit in an open window, bathroom, or laundry area where it may come in
contact with water.
7. The Flush Fit Register Booster
is designed for indoor use only.
8. Never insert any object or allow any object to enter the Flush Fit Register Booster
through the bottom or top grilles, as this may damage the unit or cause it to malfunction.
9. Do not use the Flush Fit Register Booster
near flammables such as gasoline, paint, or natural gas.
10. The Flush Fit Register Booster
is intended for use as described in the instructions only. Other use may cause fire, electrical shock, damage to the unit, or injury to persons and will void any warranty by the manufacturer.
11. Do not use strong detergents or flammable liquids to clean the Flush Fit Register Booster
.
12. The housing of your Flush Fit Register Booster
is sealed at the factory. THERE ARE NO SERVICEABLE PARTS INSIDE. Attempting to open the housing will expose you to dangerous electricity, may cause fire and will
void any and all warranty.
(4” X 10”) WALL REGISTER APPLICATIONS
INSTALLATION
IMPORTANT WARNINGS
1. Drill (two) holes with a 3/16” drill bit from the bottom side of the Flush Fit Register Booster
grille. The holes should be drilled in the pre-molded location as pictured below.
2. Secure the Flush Fit Register Booster
in place.
ADAPTOR PLATE SOLD SEPARATELY FOR REGISTER SIZES:
6” X 10”, 4” X 12”, 6” X 12”
FITS 4” X 10” FLOOR & WALL REGISTERS
NEVER EXPOSE YOUR FLUSH FIT REGISTER BOOSTER™ TO TEMPERATURES OVER 140°F (60°C)
DO NOT INSTALL IN CEILING.
WALL MOUNT DRILL HOLE LOCATION
The rotary Set Point knob selects
the automatic on/off temperature
setting for both heating and cooling.
Press mode button to select operation:
Auto
Fan
Heat
Cool
Press the fan speed
button to toggle
through the
five speeds.
Speed Adjustment:
OPERATION SETTINGS
The booster fan will turn on within a few minutes of the third or fourth cycle.
Allow 24 hours for optimal on/off operation. The unit will continue to monitor conditions/operation in an attempt to further optimize the booster fan performance. Leave the unit plugged in for a full 24 hours. If removed from power
source the learned information will be lost and the unit will reset. The fan may miss a cycle or turn on outside of a cycle, but will continue to self correct.
indicator
Apply power and ensure the orange auto mode indicator light is lit.
IMPORTANT NOTICE
Flush Fit Register Booster
1.
2.