Installation Guide

DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY
INSTALLED.
CAUTION: BEFORE CARRYING OUT ANY MAINTENANCE OR
SERVICING, ENSURE THE UNIT IS DISCONNECTED FROM THE
MAIN POWER SUPPLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS OR DUST.
NEVER EXPOSE THIS FAN TO TEMPERATURES EXCEEDING
140°F (60°C).
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
SUNCOURT
®
INSTALLATION INSTRUCTIONS
RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3
READ THESE INSTRUCTIONS BEFORE PLANNING YOUR INSTALLATION
PLEASE READ AND SAVE THESE INSTRUCTIONS:
1. Do not use fan in hazardous environments where the fan electrical system could provide ignition to
combustible or flammable materials.
2. Do not use fan to exhaust explosive or corrosive gases.
3. Check voltage at the fan to insure it corresponds with product nameplate.
4. Normal operation of this device may affect the supply of fresh air needed for safe operation of fuel
burning equipment. Follow safety standards, codes, and heating equipment manufacturer’s
procedures guide lines.
5. There are no user serviceable parts located inside the fan unit. Do NOT attempt to open (this will void
manufacturers warranty). Return unit to the factory with original purchase receipt for service after
obtaining a Return Goods Authorization (RGA).
6. All wiring must be in accordance with local and national electrical codes. When installed outside,
power must be supplied from a GFCI (Ground Fault Circuit Interrupter).
7. Operate unit only in the manner intended. If you have questions, contact the manufacturer.
8. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent
power from being switched on accidentally. When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag to the service panel.
9. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction.
10. This unit has an unguarded impeller. Do not use in locations where the impeller is readily accessible
to people or animals.
Page 1 of 6 WNTRDN-1214A-C06
INSTALLATION
Retain original packaging.
The fan can be mounted indoors or outdoors. (It is suggested that EPA recommendations be followed in
choosing the fan location.) The fan may be mounted directly to the system piping or fastened to a
supporting structure by means of mounting brackets provided.
FAN SPECIFICATIONS
Indoor Installation
Outdoor Installation
MOUNTING HARDWARE INCLUDED
Qty. 6
#6 Screws For Securing Duct Connection
Qty. 1
Air Pressure Indicator (Model RDK04 & RDK04-3 Only)
Qty. 4
TF104 Qty. 4 Qty. 4 Qty. 4 Qty. 4 Qty. 4 Qty. 2 Qty. 2
#8 x 1"
Self Tapping
Screw
Model
#6 x 1/2"
Machine
Screw
#6 Lock
Washer
Rubber
Washer
Mounting
Bracket
White
Couplers
Hex Nut
9.50"
10.00"
4.00"
0.875” STRAIN RELIEF
KNOCK-OUT
ELECTRICAL
BOX
COLOR:
WHITE
Electric Motor • External Rotor • Ball Bearing • Class B • Thermally Protected • Conforms To
ANSI-UL 705 & CSA 22.2 • ETL Listed • Housing Material FRABS • UV Protected • Flame Rating
UL 94V0 • Housing Color White
Page 2 of 6 WNTRDN-1214A-C06
Flat
Washer
Exterior Wall
Attic
MOUNTING
Mount the fan vertically with the outlet up. Insure the unit is plumb and level. When mounting directly to
the system piping ensure that the fan does not contact any building surface to avoid vibration noise. Use
the flexible couplers provided to secure the fan to the piping.
MOUNTING BRACKET
The fan may be further secured with the mounting brackets provided.
The flexible couplings will provide means of disconnect for cleaning the impeller and also to isolate
vibration.
OPTIONAL SUMP PIT INSTALLATION
In homes with a sump pit, a sump pit
cover, or dome, can be mounted and
sealed over the sump pit opening. Fittings
in the sump pit cover are used to attach
the pipes for water and radon gas
discharge. All gaps in the cover should be
sealed air tight.
Page 3 of 6 WNTRDN-1214A-C06
NOTE: Rubber washer must be
placed between bracket and
housing.
Radon discharge
Sump pit cover
Sump Pit
Water discharge
ELECTRICAL WIRING
The fans operate on standard 120VAC 60Hz. All wiring must be performed in accordance with the
National Electrical Code and state and local building codes. A qualified electrician should perform all
electrical work. Outdoor installations require the use of UL Listed watertight conduit and power supplied
from a GFCI (Ground Fault Circuit Interrupter).
ELECTRICAL CONNECTION
Connect wiring with terminal block provided, observing proper connections.
CONDENSATION & DRAINAGE
Condensation can form in the piping of a mitigation system when the air in the piping is chilled below its
dew point. This can occur at points where the system piping goes through unheated space such as an
attic, garage or outside. The system design must provide a means for water to drain back to a slab hole
to remove the condensation. The fan MUST be mounted vertically plumb and level, with the outlet
pointing up for proper drainage through the fan. Avoid mounting the fans in any orientation that will
allow water to accumulate inside the fan housing. The fans are NOT suitable for underground burial.
A condensate bypass should be installed in the outlet ducting as shown below. This is particularly true
in cold climate installations, which require long lengths of outlet ducting or when the outlet ducting is
likely to produce large amounts of condensation because of high soil moisture or outlet duct material.
Schedule 20 piping and other thin-walled plastic ducting or
aluminum downspout piping will normally produce much more condensation than Schedule 40 piping.
Fan Wire
Green
Black
White
Ground (G)
AC Line
AC Neutral
Connection
MOTOR
120VAC, 60Hz, TP
GREEN (GROUND)
GREEN (GROUND)
BLACK (LINE)
BLACK (LINE)
BROWN
WHITE (NEUTRAL)
WHITE (NEUTRAL)
N L
120VAC, 60Hz
CUSTOMER CONNECTIONS
PRE-WIRED FACTORY
CONNECTIONS
Page 4 of 6
WNTRDN-1214A-C06
WIRING SCHEMATIC
“SYSTEM ON” INDICATOR
Install a “system on” indicator to confirm status. A pressure indicator, manometer, or vacuum alarm is
recommended for this purpose. The Suncourt Air Pressure Indicator is included with models RDK04
and RDK04-3.
SLAB COVERAGE
The Suncourt Radon Fan provides coverage up to 2000 sq. ft. per slab penetration depending on type
of sub slab material. If one slab penetration does not sufficiently mitigate the Radon then additional
slab penetration points can be added as required.
Detailed Radon information is available on the EPAs website at: http://www.epa.gov/radon/
The bypass is constructed with a 45 degree
Wye fitting at the bottom of the outlet stack.
The bottom of the Wye is capped and fitted
with a tube that connects to the inlet piping.
The condensation produced in the outlet stack is collected in the Wye fitting and drained through the
bypass tube. The bypass tubing may be insulated to prevent freezing.
MAINTENANCE
Inspect the product at least once every 12 months for excessive dust and dirt build up on the impeller
(more often in dusty environments). Clean as necessary. The unit must be disconnected from power
during inspection and/or cleaning.
Failure to install a proper condensate collection system voids the product warranty.
Page 5 of 6 WNTRDN-1214A-C06
Condensate bypass parts list
(1) 3" or 4" 45DEG PVC Wye
(1) 3" or 4" 45DEG PVC Strt Elbow
(1) 3" or 4" x 1-1/2" PVC Bushing
(1) 1-1/2" x 1" PVC Flush Bushing
(1) 1" x 5' PVC
(1) 1" x 3/8" x 3' pipe wrap
(1) 3" or 4" 90DEG PVC Elbow
(3" or 4" depending on your installation)
The bypass is constructed using (2) 45
degree Wye fittings mounted above and
below the fan. The Wye’s divert the fan and
allow the condensation to bypass the fan via
a 1” drain tube.
Condensate bypass parts list
(2) 3" or 4" 45DEG PVC Wye
(2) 3" or 4" 45DEG PVC Strt Elbow
(2) 3" or 4" x 1-1/2" PVC Bushing
(2) 1-1/2" x 1" PVC Flush Bushing
(1) 1" x 5' PVC
(1) 1" x 3/8" x 3' pipe wrap
(3" or 4" depending on your installation)
Wye
Exterior Wall
Wye
FIVE YEAR LIMITED WARRANTY
Subject to the following limitations, Suncourt Inc. (manufacturer) warrants that the fan will, for 5
(five) years from date of original purchase, remain free from appearance of defects in workmanship
or materials. This warranty is subject to the following limitations: (a) manufacturers liability is
limited to the replacement or repair of the unit, as decided by the manufacturer; (b) a defective unit
must be returned, prepaid, with proof of purchase, to Suncourt; and (c) this warranty does not
apply to defects resulting from the alteration, abuse, accidental damage, unauthorized repair, or
misuse of the unit. This warranty is given in lieu of all other warranties, guarantees, and conditions
on manufacturer’s part, and the manufacturer shall have no tortious or other liability in respect to
this fan. There is no implied warranty of merchantability and fitness for a particular purpose.
Suncourt shall not be liable for any direct, indirect, special, incidental or consequential damages
arising from, or relating to, the fan or the performance of it. Suncourt’s maximum liability shall not
exceed the amount of the purchase price of the fan. The sole remedy under this warranty shall be the
repair or replacement of the product.
WARRANTY RETURN
Call Suncourt at 1.800.999.3267 for a Return Goods Authorization (RGA) number. Please have date
of original purchase available.
Mark the RGA number clearly on the return shipping box. We do not accept returns without a valid
RGA number.
Package the unit using the original packaging including the styrofoam inserts to avoid damage in
shipping.
Page 6 of 6 WNTRDN-1214A-C06