Warranty

INSTALLATION
INSTRUCTIONS
FOR
THE
THRUWALL
ROOM
TO
ROOM
FANTM
MODEL:
TW208P
READ
AND
SAVE
THESE
INSTRUCTIONS
IMPORTANT
NOTICE
WARNING·
To
Reduce
The
Risk
Of
Fire
Or
Electric
Shock,
Read
These
Instructions
Before
Installing
Your
Thruwall
TW20BP
Room
To
Room
Fan.
This
fan
is
not
to
be
installed in an
outside
wall.
Do
not
use
in
wet
or
damp
locations.
Do
not
install in fire rated walls.
Do
not
use
in a
window.
Do
not
connect
to
a
secondary
remote
speed
control.
Not
for
bathroom
use.
With
the
use
of
any
electrical
appliance,
it
is
important
to
observe
all
basic
precautions
to
minimize
the
risk
associated
with
use,
such
as
electrical
shock,
fire,
or
injury
to
persons.
If
you
have
doubts
or
are
unfamiliar
with
this
type
of
installation
work,
seek
the
services
of
a
qualified
electrician.
Suncourt
assumes
no
responsibility
for
installation
of
the
ThruWall
FanTM.
For
your
safety
and
protection
follow
all
instructions
and
adhere
to
applicable
building
and/or
electrical
codes.
NEVER EXPOSE YOUR THRUWALL TO TEMPERATURES OVER 140°F (60
0
e)
Warning.
To
Reduce The Risk
Of
Fire, Electric Shock
Or
Injury
To
Persons, Observe The Following:
Installation
work
and
electrical
wiring
must
be
done
by
qualified
person(s)
in
accordance
with
all
applicable
codes
and
standards,
including
fire·rated
construction.
When
cutting
or
drilling
into
wall,
do
not
damage
electrical
wiring
or
other
hidden
utilities.
Prior
to
installation
of
the
TW20BP
fan,
switch
power
off
at
service
panel
and
lock
service
panel
to
prevent
power
from
being
switched
on
accidentally.
When
the
service
disconnecting
means
cannot
be
locked,
securely
fasten
a
prominent
warning
device,
such
as
a tag,
to
the
service
panel.
STEP
BY
STEP
INSTRUCTIONS
Step
1. Depending
on
your needs, the ThruWall™ can be installed high or low on the wall. Please
note that warm air rises, thus is found near the ceiling. Conversely, cold air falls and
is
found near
the floor. The temperature
of
the air near the ceiling may be as much as 1
OaF
to 15°F higher than
near the floor.
Start by making sure that there are NO studs, water, drain, electrical
or
other
obstructions
in
the wall where you wish to install the unit. Please see the airflow direction label
on
the housing.
Step14.
Position the unattached plastic grille over the metal sleeve that was just inserted
so that the
logo
on
the center
of
the grille is right side up and that one of the mounting
holes
is
in
the top center. Adjust the metal sleeve so that the three U shaped cut outs
in
the
flange match up with the mounting
holes
in
the grille. Mark the location
of
all 3 wall
anchors.
Step
15.
Drill the holes
on
the wall for the anchors with a sharp 3/16" drill bit. Install wall
anchors and screw the grille down snugly.
DO
NOT
OVERTIGHTEN!
OPERATION
INSTRUCTIONS:
Step
2. Place template flush against wall. Check for level and tape
in
place. Note: The wall that the
template
is
taped to will be the fan output side.
The
ThruWaWM
is
equipped with a variable speed controller.
There is a speed adjustment knob on the output side
of
the fan.
Step
3. Cut out the opening with a small drywall
saw.
Take
care not to damage the edge of the
drywall since you will be installing drywall anchors close to the hole to mount the grille.
Step
4.
Insert the grille with fan attached into the hole that you just cut. Make sure the fan is level
and that the grille completely covers the opening. Mark the location of the 4 mounting holes.
Step
5.
Remove fan from hole and drill mounting holes with a sharp 3/16" drill bit. Insert wall
anchors
in
mounting holes.
Step
6.
Project the edge of the round section of the cutout onto the inside of the other wall board
in
three places, approximately 120
0
apart. Use a small square or a piece of cardboard that has
an
exact 90
0
angle to mark the cutout points
on
the inside
of
the other wall.
Step
7.
Use a small pin or very small drill bit (1/32"
or
smaller) to punch or drill these three marks
to the outside
of
the other wall.
Step
8. Place the sleeve without the grille attached, against the outside of the wall and center its
location using the three holes that you made. Then trace the outside of the sleeve with a pencil.
Turning the switch to the right will allow you to adjust speed from low to high as you desire.
The unit is
in
the off position when the speed control knob is turned all
of
the
way counter
clockwise.
Thank you for buying this Suncourt product.
PLEASE
READ
THESE
INSTRUCTIONS
BEFORE
STARTING
INSTALLATION
Cut the circular opening with a small drywall
saw.
Cut inside the pencil line.
Take
care not to damage
the edge
of
the drywall.
You
will be installing drywall anchors close to the holes to mount the grille.
Step
9.
Take
the electrical box cover off of the molded
on
electrical box
and
install a 3/8" strain
relief that is appropriate for your 120VAC power supply wire and/or conduit.
The
ThruWall™ fan moves air from room to room quietly and efficiently. Simple to install
in
any frame wall from 3-3/4" to 6-1/2" thick. A high quality Thermally Protected motor
with
balanced fan blade moves up to 150 CFM. Moves heated or cooled air between
rooms.
Excellent for ventilation! The ThruWall™ can be mounted
in
any normal drywall
or paneled stud construction wall up to
6-112"
maximum total thickness.
The grilles
of
your ThruWall fan may be painted to suit any decor. Thoroughly wash the
grilles with mild household detergent, dry completely, and spray with a quality, fast
dry,
spray paint.
Step
10.
Insert your 120VAC power supply wires through the strain relief and use the provided
wire nuts to connect the white (common),
black (hot), and green (ground) wires from the TW208P
ThruWall
fan to the appropriate common, hot and ground wires of your incoming power wires.
Step
11.
Check to see that your strain relief is securely fastened and re-attach the electrical box
cover.
DO
NOT
OVERTIGHTEN!
Step12.
Insert the metal sleeve with grille into the cutout opening (fan output side) and screw the
grille down snugly.
The installation of your ThruWall™ fan is not difficult, but the cutouts must be accurate.
In
the carton you will find:
(1)
Telescoping metal sleeve with plastic grille attached
(1)
Telescoping metal sleeve without grille attached
(1) Loose grille
Step13.
Insert the other metal sleeve into the cutout opening (fan suction side) and snug the flange
up against the wall material.
(1) Template
(7) #6 Screws
(7) Wall Anchors
(3) Wire Nuts
ONE
YEAR
LIMITED
WARRANTY
Subject to the following limitations, Suncourt Inc. (manufacturer) warrants that the ThruWall
FanTM
will, for 1 (one) year from date
of
original retail purchase, but not exceeding 2 (two) years
from date
of
manufacture, remain free from appearance
of
defects
in
workmanship
or
materials.
This warranty is subject to the following limitations: (a) manufacturer's liability is limited to the
replacement or repair
of
the unit, as decided by the manufacturer; (b) a defective unit must be
returned, prepaid, with proof
of
purchase, well packaged to avoid damage
in
transit; and (c) this
warranty does not
apply to defects resulting from the alteration, abuse, accidental damage,
unauthorized repair, or misuse
of
the unit. This warranty is given
in
lieu
of
all other warranties,
guarantees, and conditions on manufacturer's part, and the manufacturer
shall have
no
tortious
or other
liability
in
respect to this ThruWall Fan™. Ship unit to Suncourt Inc. only after obtaining a
Return Goods Authorization (RGA) number. Returns without this RGA number
will not be
accepted.
Actual product appearance may differ from illustrations.
Suncourt reserves the right to modify any
or
all
of
its products' features, designs, components
and specifications without notice.
SUNCOURT INC.
P.O.
Box 40
Durant, IA 52747-0040
1.800.999.FANS
(3267)
www.suncourt.com
WNT208-0711-C01
PRINTED
IN
CHINA

Summary of content (1 pages)