IMPORTANT SAFETY INSTRUCTIONS
INSTALLATION INSTRUCTIONS FOR ZONEMASTER™ MOTORIZED ADJUSTABLE DAMPER
READ AND SAVE THESE INSTRUCTIONS
WARNING
To reduce the risk of fire, electric shock or injury to persons, observe all instructions. The ZoneMaster™ has been designed to operate on 24 Volt AC, 60 Hz.
Maintain a minimum clearance of 4” (10 cm) from any combustible material or surface to the Transformer and/or the ZoneMaster™ electric motor.
This damper is designed to control the flow of heated or cooled air in air distribution systems only. Never close more than 20% of the total air distribution system at a time. The
restricted airflow through a furnace or air handler may cause damage to the air delivery and /or air conditioning equipment. This damper must never be used to control the flow
of combustion air, flue gas or other toxic or hazardous gases or applications where failure of the damper can cause damage to persons, property or equipment and/or create a
risk of fire, suffocation or death.
IMPORTANT NOTES
The following will be required to complete the installation:
A standard low voltage Heat-Cool wall thermostat, designed for gas furnaces.
• Electrical wire, 2-conductor, 20 Gauge (CL-2 or Bell Wire) to connect the Transformer to the Damper via the wall thermostat. If the total length of wire exceeds 80 feet (25 m),
use 18 gauge wire. If two or more Dampers are wired in parallel (maximum 2 Dampers per each included 20 VA Transformer), use 18 gauge wire.
• If you are mounting the Damper between floor joists in flexible duct, you will need two duct supports.
Aluminum foil duct tape.
BENEFITS
The ZoneMaster™ will allow you to individually control the temperature of a room in your home. e.g. An unused room does not have to be heated or cooled to the same
temperature as the remainder of the home. In the winter you may want a bedroom a little cooler than the rest of the home. The baby’s room you may want a little warmer than
the rest of the home in the summertime. You control your comfort and save significantly on energy use.
SELECTION
Choose a normally closed Damper (ZCxxx) if you want the airflow restricted when the Damper is un-powered. This is typical for the thermostatic control.
Choose a normally open Damper (ZOxxx) if you want the airflow restricted when the Damper is powered.
INSTALLATION INSTRUCTIONS
Consult the Wiring Diagram when planning the installation. Begin by determining the location of the Damper, the thermostat and the Low Voltage Transformer. Then determine
the route you will be running the wires from the Transformer to the thermostat and onwards to the Damper. Once you have this planned, proceed as follows.
DAMPER UNIT INSTALLATION
For metal duct, remove a 6” (15 cm) section of duct at an existing joint so you will have one crimped duct end and one straight duct end. Slide the Damper unit in place so that
the ends are inserted at least 1” (2.5 cm) at each end. The crimped duct work end should be inserted no more than 2" (5 cm) inside the female end of the Damper or it may
interfere with the Damper plate. The Damper is non-directional so it may be installed facing either direction of the airflow. Rotate the Damper so that you can easily access the
electric terminal block. Complete the installation by securing the Damper with the #6 sheet metal screws supplied. Finish the installation by covering the seams in the duct with
a good quality aluminum foil duct tape.
For flexible duct, cut the flexible duct and slide the ends over the ends of the Damper unit. You will need to support the Damper with a couple of standard duct supports
available at Home Centers. Complete the installation by securing the Damper to the flexible duct with a good quality aluminum foil duct tape or nylon cable ties. Take care to
ensure that the outer jacket and insulation do not interfere with the Damper mechanism. Make sure that the chosen method to secure the Damper to the duct does not deform
the body of the Damper pipe. If the Damper pipe is severely “out of round”, the spring return mechanism may not function properly.
THERMOSTAT INSTALLATION: (THERMOSTAT NOT INCLUDED)
The thermostat should be located within the space served by the vent(s) whose airflow is controlled by the new Damper(s). Mark the location of the thermostat mounting hole
in the back plate of the thermostat and install the fastening hardware normally supplied with the thermostat. Do not mount the thermostat on an outside wall. Locate the
thermostat approximately 5’ (1.5 m) above the floor and away from drafts and direct sunlight. DO NOT screw the thermostat to the wall at this time.
For general ventilation control use only.
Do not use to control the flow of hazardous, corrosive, flammable or explosive materials and vapors.
Never expose this product to temperatures exceeding 140°F (60°C).
Always leave this product accessible for maintenance, cleaning and repair.
Before installing or servicing this product, unplug the Transformer.
Suncourt® Inc. assumes no responsibility for the installation of the
ZoneMaster™
.
Suncourt® does not provide electrical connection information beyond what is provided herein.
If in doubt, contact a competent contractor.
For your safety and protection follow all instructions and adhere to applicable building and electrical codes.