Owner's Manual

14
7. If after repeating steps 4 to 6 unit does not light, then:
-Push in control knob and turn counterclockwise to “PILOT” (Figure 3).
-As you are depressing the control knob, place long stem lighter (See figure OO on page 3)
through the hole located in between the igniter and the variable control knob to light the pilot
(Figure 5).
-Repeat step 6.
8. Push in and turn the control knob to the “HIGH”, then release control knob. If you want a lower
temperature, push in the control knob and turn counterclockwise to the “LOW” (Figure 5).
Note: If pilot fails to remain lit, all valves should be closed and a waiting period of at least 5
minutes should pass before attempting to light.
If you experience any ignition problem please consult “Troubleshooting” on page 19.
Caution: Avoid inhaling fumes emitted from the heaters first use. Smoke and odor from the
burning of oils used in manufacturing will appear. Both smoke and odor will dissipate after
approximately 30 minutes. The heater should NOT produce thick black smoke.
Note: The burner may be noisy when initially turned on. To eliminate excessive noise from the
burner, turn the control knob to the PILOT position. Then, turn the knob to the level of heat
desired.
Note:
In Normal condition, the height of flame
is 2/3 height of glass
tube under Hi position.
The height of flame is
1/3 height of glass
tube under Low
position. The flame is
stable and bright.
No noise nor black
smoke.